Televis System connection
MECHANICAL INSTALLATION
The device is designed for wall or panel mounting on DIN guides.
Make a hole 70x45 mm and insert the device, securing it with the
fixings provided. Do not install the device in damp and/or dirt-laden
areas; It is suitable for use in places with ordinary or normal levels of
pollution. Ensure that the area around the device cooling slots is
adequately ventilated.
ELECTRICAL CONNECTIONS
Important! Switch off the device before working on the electrical connections.
The device is equipped with screw terminals for connecting electric cables of 2.5 mm 2 maximum cross-section (one wire per terminal in the case of
power connections): for the capacity of the terminals, see the label on the device. The relay outputs are voltage-free. Do not exceed the maximum
permitted current; for higher loads, use a contactor with sufficient power capacity. Make sure that power supply is the correct voltage for the device.
Note that the length of the wiring used for analog inputs and outputs wiring can affect the EMC (electro-magnetic compatibility) characteristics of the
device and it is therefore important to take great care when wiring up the device; we recommend that you do not use cables over 3 metres in length.
The probe cables, power supply cables and the TTL serial cable should all be kept separate from the power cables.
RESPONSIBILITY AND RESIDUAL RISKS
Quintex GmbH shall not be liable for damage resulting from:
- installation/uses other than those specified and, in particular, which do not comply with the safety requirements set out in the regulations and/or
stated herein;
- use on panels that do not provide adequate protection against electric shock, water or dust when assembled;
- use on panels that allow access to dangerous parts without having to use tools;
- tampering and/or modification of the product;
- installation/use on panels that do not comply with the current standards and regulations.
DISCLAIMER
This document is the exclusive property of Quintex GmbH and may not be reproduced or circulated unless expressly authorized by the latter. All
possible care has been taken to ensure the accuracy of this document; nevertheless, Quintex GmbH cannot accept liability for any damage resulting
from its use. The same applies to any person or company involved in preparing and editing this document. Quintex GmbH reserves the right to
make changes or improvements at any time without notice.
CONDITIONS OF USE
PERMITTED USE
For safety reasons, the device must be installed and used according to the instructions provided. In
particular, parts carrying dangerous voltages must not be accessible in normal conditions.
The device must be adequately protected from water and dust according to the application, and must also
I_Park Tauberfranken 13
only be accessible using tools (with the exception of the front panel).
D-97922 Lauda-Königshofen
The device is suitable for use in household refrigeration appliances and/or similar equipment and has been tested
Tel.: +49 (0)9343/6130-100
for safety aspects in accordance with the harmonised European reference standards. It is classified as follows:
• with regard to its construction, as a built-in automatic electronic control device;
Fax.: +49 (0)9343/6130-105
• with regard to its automatic operating characteristics, as a type 1B control type device;
• with regard to its software class and structure, as a Class A device.
www.quintex.info
USES NOT PERMITTED
The device must not be used for applications other than those described.
Note that the relay contacts provided are of a functional type and therefore subject to malfunction: any
protection devices required by product standards, or suggested by common sense, must be installed
externally to the instrument for obvious safety reasons.
The device can be connected to Televis remote control systems through a TTL
serial port (use the TTL- RS interface module 485 BUS ADAPTER 130 or 150), or,
on certain models (IRE168DS), via a direct RS-485 connection. To configure the
device for this purpose, open the folder identified by the "Add" label and use
parameters "dEA" and "FAA".
IMPORTANT! CHECK THE AVAILABILITY OF COMPATIBLE MODELS
WITH REMOTE CONTROL SYSTEMS.
Dimensions
61.6mm
70.2mm
5.2mm
43.6mm
56.4mm
7/7