Heating in-between seasons
If you heat the stove in between seasons, when the outside
temperatures are higher, the flue gases may not be able to
escape completely and this may lead to disturbances in the
chimney draught, especially if the temperatures are rising
suddenly. The stove has to be charged with less wood then
and the primary air has to be increased so that the wood can
burn down faster (with visible flames) and thus the chimney
draught can stabilize.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description
Gasket Ø8mm, L=1800 mm
Gasket 8x2, L=416 mm
Gasket 15x8, L=1950 mm
Keramott
Description
Bottom left, Keramott
Bottom rear, Keramott
Bottom right, Keramott
Rear, Keramott
Side component left, Keramott
Side component right, Keramott
Wood retainer, Keramott
Baffle plate rear, Keramott
Grate
Other parts
Description
Chester door
Door handle
Chester door glass
Glass cleaner ½ litre
Stove lacquer
Accessories
You can obtain floor plates of glass or steel or care products from your certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplace must not be attered.
Maintenance
To clean the glass, please use a specialised product such as Thermohit glass cleaner. Lacquered surfaces are to be cleaned
only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel surfaces. Only gaskets in
good order ensure the proper function of your stove!
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if necessary more often,
e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by the chimneysweeper. Your
chimneysweeper will inform you of the necessary inspection intervals. An expert should inspect the stove annually.
No.drawing Part number
10
710049
11
710096
12
718571
No.drawing Part number
1
719171
2
719173
3
719172
4
719176
5
719177
6
719178
7
719179
8
719181
9
716408
No.drawing Part number
13
7119165
14
771096
15
719156
--
640070
--
650002
7
Chimney fire
A chimney fire may occur, due to sooting and deposits in the
chimney, if impropes or humid fuel is used. In case of a
chimney fire close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an expert
inspect your chimney for cracks and air-tightness after the
burning out of the chimney.