Herunterladen Inhalt Inhalt Diese Seite drucken

Johnson Pump SPX AquaT Bedienungsanleitung Seite 13

Schiffstoilette manuell betrieben
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
Winterization
Drain the complete system both as a protection against frost damage and
to avoid the growth in the pipework of bacteria that could cause unpleasant
smells.
HAZARD RISK:
Seacocks opened by mistake. In case you leave the toilet disassembled
and if the sea cocks are opened when the boat is afloat, water will flood in
by causing the sinking of the boat and the possible loss of life. Therefore, it
is indispensable to attach a warning notice to the seacocks and, if possible,
wire the seacocks shut. Remember to attach warning notices!
WARNING:
The use of anti-freeze is not recommended, as it is not possible to ensure
that the product penetrates the whole toilet system If, for any reason, an
anti-freeze compound is employed it will have to be a glycol-based one.
Open any secondary valve.
Remove the base drain plug.
Loosen hose clips and disconnect all the hose ends from the
seacock hose tails, the hose toilet tails, and any secondary valves.
Pump the handle to drain the toilet pump and ensure that all water
is properly drained from the toilet system.
If you not are going to disassemble the toilet:
Reconnect all hose ends and secure them with their hose clips.
Firmly replace the base drain plug.
Fasten down seat, lid and pump handle to prevent any use, and
attach a warning notice.
Overhaul
You need a service kit containing all wearing parts refer to the list of parts
for further details.
CAUTION
For the safety of your craft and your crew, use only genuine spare parts.
Remove the pump assembly as follows
Loosen hose clips; disconnect the inlet hose and the link hose
from the top of the pump.
Remove the 2 screws which secure the discharge flange and
elbow to the pump cylinder.
DO NOT remove the hose clips and hose from the discharge
elbow.
Remove the 4 screws which secure the pump cylinder to the base.
Lift off the pump assembly and pick up the bottom valve gasket
and the joker valve.
Dismantle the Pump assembly as follows
Remove the 6 screws that secure the valve cover.
Open the flush control before lifting off the valve cover assembly
and picking up the top valve gasket and the valve seat.
Reassemble the pump as follows
Push on the new piston O-ring.
Follow the servicing instructions for seal replacement and fit the
new seal assembly, the piston assembly and the handle.
Lubricate pump cylinder bore with Vaseline.
Locate the valve seat on cylinder top, locate the top valve gasket
on its pegs on the cylinder top and open the flush control before
refitting the valve cover.
Refit Pump assembly on the toilet as follows
Locate the bottom valve gasket on its pegs on the base and locate
the joker valve in the discharge elbow.
Secure the discharge flange to the pump cylinder before securing
the cylinder to the base.
Examine all hoses throughout their length for chafe, kinks and
splits under hose clips, check all hose clips for corrosion and
replace worn out or damaged parts .
Reconnect all hose ends and secure them with their hose clips.
Ensure that the base drain plug is securely tightened.
Do not lubricate the top or bottom valve gaskets, and do not apply sealing
compounds to any gasket or hose connections.
13
Original instructions

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis