Product speci cations

Power supply

voltage: 230VAC +/- 10%
frequency: 50 – 60 Hz
output: 1200W
the use of a generator is permissible if it is able to deliver adequate power and the
output delivers clean sinus form voltage in the correct frequency range (50 - 60 Hz).
safety class: Class I
W A R N I N G
!
The unit must always be connected to a supply network with a fuse rated at at least 10A
and at most 16A. The unit does not have an internal fuse.
An earth bonded wall socket should always be used on safety grounds (Class I).
W A R N I N G
!
The unit does not feature an on/off switch, as soon as the plug is inserted in the socket
the unit will be powered up.

Working environment

temperature: -5°C to +40°C
humidity: 0 – 90%, non-condensing
IP 20
no higher than 2,000 metres above sea level

Instructions

Pictograms

The pictograms appearing on the iDuctor have the following meanings:
Caution! This equipment generates a magnetic field which can erase magnetic
data from credit cards and the like.
Caution!
Not to be used by persons with a pacemaker.
Caution!
This equipment includes components which may reach high temperatures.