Herunterladen Inhalt Inhalt Diese Seite drucken

Ec Declaration Of Conformity; Troubleshooting - EGO LB4800E Gebrauchsanweisung

56 volt lithium-ion kabelloser laubbläser
Vorschau ausblenden Andere Handbücher für LB4800E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16

EC DECLARATION OF CONFORMITY

EN
We, CHERVON EUROPE LTD.
47 CASTLE STREET, READING, RG1 7SR, UNITED KINGDOM
Declare that the product 56V lithium-ion cordless blower LB4800E, Complies with
the essential health and safety requirements of the following Directives:
2006/42/EC, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2000/14/EC
Standards and technical specifications referred to:
EN 60745-1, EN 15503, EN 62233, EN 55014-1, EN 55014-2
Measured Sound Power Level: 99.81dB(A), Guaranteed Sound Power Level: 100dB(A)
The conformity assessment followed was according to Annex V of the Directive
Peter Melrose
Vice President Of Chervon Europe
20/12/2014
26
56V LITHIUM-ION CORDLESS BLOWER — LB4800E
Dong Jianxun
Quality Manager Of Chervon

TROUBLESHOOTING

PROBLEM
CAUSE
◾ ◾
The battery pack is not
attached to the blower.
◾ ◾
No electrical contact
between the blower
and battery
◾ ◾
The battery pack is
depleted.
Blower doesn't
◾ ◾
The battery pack or
work.
blower is too hot.
◾ ◾
The switch is operated
too frequently in a
short time. PCB self-
protection.
◾ ◾
Excessive wearing of
The air velocity
motor fan.
decreases
◾ ◾
The air inlet is blocked
obviously.
by debris.
56V LITHIUM-ION CORDLESS BLOWER — LB4800E
EN
SOLUTION
◾ ◾
Attach the battery pack to the
blower.
◾ ◾
Remove battery, check
contacts and reinstall the
battery pack.
◾ ◾
Charge the battery pack.
◾ ◾
Cool the battery pack and
blower until the temperature
drops below 67°C.
◾ ◾
The blower is equipped with
soft start technology. Wait for
the motor to start up smoothly
when the trigger switch is
depressed.
◾ ◾
Contact EGO service center for
repair.
◾ ◾
Remove the battery pack, clear
the debris.
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis