30

7 - TROUBLESHOOTING

PROBLEM
1. Softener fails
A. Electrical service to unit has been
to regenerate
interrupted
B. Timer is not operating properly
C. Meter cable disconnected
D. Jammed meter
E. Defective valve drive motor
F. Improper programming
2. Softener delivers
A. By-pass is opened
hard water
B. No salt in the brine tank
C. Injector or screen is blocked
D. Insufficient water into the brine tank
E. Hardness from the hot water tank
F. Leak at the distributor tube
G. Internal valve leak
H. Flow meter jammed
I. Flow meter disconnected
J. Improper programming
3. Unit uses
A. Improper brine refill setting
too much salt
B. Excessive water in the brine tank
C. Improper programming
4. Loss of water
A. Iron build up in line to softener
pressure
B. Iron build up in the softener
C. Inlet of the valve plugged due
5. Loss of resin
A. Top distributor missing or broken
through
B. Air in water system
drain line
C. Drain line flow control
is the wrong size
6. Iron in softened A.Fouled resin bed
water
B.Iron exceeds the recommended
parameters
CAUSE
A. Assure permanent electrical service
B. Replace the timer
C. Check the meter connection to the
D. Clean or replace the meter
E. Replace the drive motor
F. Check the programming and reset as needed
A. Close the by-pass valve
B. Add salt to the brine tank and maintain the salt
C. Replace or clean the injector and screen.
D. Check the brine tank fill time and clean
E. Repeated flushing of the hot water
F. Make sure the distributor tube is not cracked.
G. Replace seals and spacers and/or piston
H. Remove the obstruction from meter
I. Check the meter connection
J. Check the programming and reset as needed
A. Check salt usage and salt setting
B. See problem n°7
C. Check the programming and reset as needed
A. Clean the line to the softener
B. Clean the valve and resin bed
C. Remove the piston and clean the valve
A. Add or replace the top distributor
B. Ensure the presence of air check
C. Ensure the drain line flow control
A. Check backwash, brine draw and
B. Contact the dealer
CORRECTION
(check fuse, pull chain or switch)
timer and the meter cover
level above the water level
the brine flow control if it's blocked
tank is required
Check the O' ring and tube pilot
to the timer and the meter cap
system in the brine tank
is sized correctly
brine tank refill ; increase frequency
of regeneration; increase backwash time
7700 SXT