Connectors
I/O Connector
6–pin terminal block
For an example diagram, see Connection Diagrams on page 18.
Func-
P-
tion
i-
n
0 V DC (-) 1
2
DC
output
3
Config-
urable
6
(Input or
Output)
Notes
Can be used to power auxiliary
equipment.
Note: This pin can only be used
as power out.
Digital input – Connect to pin
1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected
to pin 1 when activated,
floating (unconnected) when
deactivated. If used with an
inductive load, e.g. a relay,
a diode must be connected
in parallel with the load, for
protection against voltage
transients.
15
AXIS F41 Main Unit
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC,
open drain,
100 mA