BTL7-S5_ _ (_)-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
8
Technical data (continued)
8.7

Connection to the evaluation unit

The maximum sampling frequency f
current value is available with each sampling, can be found
in the following graphic:
f
in Hz
A,max
Fig. 8-1:
Maximum sampling rate depending on the nominal length
(for position output) The maximum sampling rate for
velocity output is limited to 3.3 kHz.
The maximum SSI clock frequency f
the cable length
1)
:
f
in kHz
Clk,max
Fig. 8-2:
Maximum SSI clock frequency depending on the cable
length
www.balluff.com
, at which a new
A,max
is dependent on
CLK, max
Ignition protection "d"
Flameproof enclosure
The minimum sampling rate f
A,min
Nominal length in mm
Cable length in m
1) For longer length: required cable cross-section ≥ 0.6 mm
is 62.5 Hz.
(1) 1 magnet
(2) 2 magnets
(only BTL7-S510...)
2
or ≤ AWG19
english