** When selecting pressure components, ensure that the overload pres-
sure P
max
It is possible that the pressure cell can be deformed when the overload
pressure P
level of the pressure spike).
The "diesel effect" caused by entrapped air can result in pressure
spikes that far exceed the maximum pressure. The nominal pres-
sure P
higher than the nominal pressure of the system to be measured.
Input data
Switching cycles
Pressure port
Material for the components
that come in contact with the
substance
Material of membrane
Tightening torque
Temperature of substance
50
will not be exceeded.
is exceeded (depending on the duration, frequency and
max
of the pressure component (sensor/switch) should be
n
≥ 100 million
¼" BSP; ¼" NPT
Stainless steel EN/DIN 1.4548 / FKM
(with replaceable seal)
Stainless steel EN/DIN 1.4548
Max. 35 Nm
-40 ... +150°C / -40 – 302°F