Herunterladen Inhalt Inhalt Diese Seite drucken

Olimpia splendid B0152 Bedienungsanleitung Seite 38

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
MODIFICATION OF OPERATING PARAMETERS
With the thermostat in the OFF condition, press the OFF key and keep it pressed. After about 10
seconds, the display will show the firmware version on the left of the screen (large characters) and
the set operating mode on the right (small characters). If no key is pressed for about 30 seconds, the
device goes back to the OFF condition; otherwise, keys V+ and V- can be used to browse through the
list of parameters, which can be changed by means of keys T+ and T-. Once all parameters have been
changed, press A/M key to store them and return to normal operation, or press the OFF key to return
to normal operation without making any changes to the parameters.
Parameter
Description
P0
Regulation differential
P1
Fan control hysteresis
Not used
P2
Temperature unit of
P3
measure
P4
Not used
Min. water temperature
P5
threshold (WINTER)
Room temperature
P6
offset
Max. water temperature
P7
threshold (SUMMER)
Manufacturer's setting From - to
0,5 K
0,4K-1K (if ° F 0,7K-1,8K)
1 K
0,4K-1K (if ° F 0,7K-1,8K)
1 = ° C
° C
2 = ° F
30° C
30
÷
50° C
-2K
-5,0 ÷ +5,0 K
20°C
10 ÷ 30°C
WARNING!
The temperature parameters
are always expressed as °C or °F
depending upon the unit of me-
asure selected (parameter 3).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis