Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
PCMM Installation Manual | 1   English

1.4.3 Technical Data

Rated Data
Electrical Data
Rated supply voltage
Rated input current
Rated input power
Permitted switch on/off frequency
Mechanical data
Weight
Dimensions (HxWxD)
Dimensions (HxWxD) with connectors
Recommended Tightening Torques
X1, X35, X36
PE block
Fusing
Circuit
24 V DC supply
Inputs/Outputs
Interface
Digital inputs
see (➜ # 135)
Digital outputs
see (➜ # 136)
Ambient Conditions, Ventilation, and Mounting Position
Storage, Transport
Ambient temperature
in operation
Humidity
in operation
Site altitude
Pollution level
Vibrations
Enclosure protection IP 20 according to IEC 60529
Mounting position
Ventilation
12
Kollmorgen | kdn.kollmorgen.com | February 2018
Max.
Example class J
Ampere rating
Cooper Bussmann
8A (Time-Delay)
LPJ8SP/DFJ8
Electrical Data
ON: 3.5 VDC to 30 VDC, 2 mA to 15 mA
OFF: -2 VDC to 2 VDC, max.15 mA
Galvanic isolation for 250 VDC
Update rate: Software 250 µs
Source or Sink type
Max. 30 VDC, 100 mA
Short circuit proof
Galvanic isolation for 250 VDC
Update rate: 1 ms
Active low or active high
(➜ # 8)
0 to +55° C under rated conditions
Relative humidity 5 to 85%, no condensation, class 3K3
according to IEC 60721-3-3
Up to 2500 meters above mean sea level without restriction
Pollution level 2 as per IEC 61010-1
Class 3M1 according to IEC 60721-3-3
Vertical
Free convection
Units
V DC
24 V ±10% see (➜ # 133)
A
W
1/h
kg
mm
174 x 50 x 111.5 see (➜ # 130)
mm
208 x 50 x 147.5 see (➜ # 130)
Nm (in-lbf)
0.2 to 0.25 (2)
Nm (in-lbf)
Example class J
Ferraz Shawmut
AJT8
PCMM
1.25
30
30
0.45
1.7 (15)

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Akc-pcm-mx serie