7.

LED Indicators

LED indicator B
LED indicator C
LED indicators B
and C
8.

Technical Data

Supply voltage
Switch
Rated current
Maximum load
Operating temperature range
Thermostat adjustment range
Floor max. limitation range
Floor min. limitation range
Floor sensor
Floor sensor resistance values
Fuse
Enclosure class
Pollution degree rating
Rated impulse voltage
Power in standby
Radio frequency range
Radio max. power
Thermostat can control external relay.
18
Green: thermostat is on, heating is off
Red: heating is on
Blue blinking: pairing is ongoing
Blue blinking quickly: factory defaults are resetting
Blue: temperature change
Blue is blinking 4 times per minute:
Floor temperature has risen higher than the set temperature limit
Blue and red blinking alternately:
faulty sensor or floor temperature min and max set values are too close
to each other
230 V -15%, +10%, 50 Hz
2-pole
16 A
3600 W
-20 ... +30 °C
5 ... 35 °C room
5 ... 50 °C floor
+25 ... +50 °C
+5 ... +40 °C
NTC, 47 kΩ/25°C, cable 4 m (extendable to 10 m)
Tabel 1, on page 2 (sensor not connected)
Max. 16 A
IP30
2
4 kV
0,1 W
2,4 ... 2,483 GHz
+3 dBm
RAK121 / © Ensto 2018