Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - DELTA DORE TYPHONE 2 SV Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TYPHONE 2 SV:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Can control 2 separate appliances
(e.g. heating, immersion heater, lighting...)
via your telephone line
• Secure control access code
• Easy to use voice synthesis technology
• Manual override controls
Choice of controls
(any 2)
Central control panel
Off-Switch or minimum
temperature
or
Immersion
heater
Hot water supply
or
Other controls...
1

TECHNICAL SPECIFICATIONS

• Mains voltage : 230V, 50Hz
• Insulation class I
• Power consumption : 4 VA
• 2 x 2Amps 230 V normally open contact
outputs (reverse NO/NC available by
software)
• 6 or 7 rings before connection
• Manual output contact control
• Access code indicator
• Output state indicators
2
MOUNTING
In order to mount the device on the wall, it must be separated from its base.
To do this, unscrew the locking screw.
After separation from the case, the base must be fixed to the wall using
screws and plugs or on a flush-mounting box
(centre-to-centre distance 60 mm) using the holes ➊.
Breakable partitions can be removed to allow the connection cable to pass,
if necessary (➋ : flush-mounting box, ➌ : wall mounting)
Heating On/Off
Fil Pilote
convector
Frost-protection
control
- 10 -
• Usable with an answering machines
• 4 languages (French, English, Spanish,
German)
• Complies with European Standard CTR21
Connections
according to use
TYPH ONE 2
SV
Remote
telephone
• Telephone line-in lightning arrester integrated
in device case
- standard 48V telephone input
- current throughput :
10kAmps with 8/20 pulse,
residual voltage < 900V
• Room case : 128 x 85 x 31 mm
• Wall mounting
Home
telephone
F
F
2
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis