2.8 Important notes for fi tting
The appliance must be handled and installed by two or
more persons - risk of injury. Use protective gloves to
unpack and install - risk of cuts.
Keep children away from the installation site.
After unpacking the appliance, make sure that it has
not been damaged during transport. In the event of
problems, contact the dealer or your nearest After-sales
Service.
Once installed, packaging waste (plastic, styrofoam
parts etc.) must be stored out of reach of children - risk
of suff ocation.
The appliance must be disconnected from the power
supply before any installation operation - risk of
electrical shock. During installation, make sure the
appliance does not damage the power cable - risk of
fi re or electrical shock. Only activate the appliance
when the installation has been completed.
Carry out all cabinet cutting works before fi tting the
appliance in the furniture and remove all wood chips
and sawdust.
If the appliance is Not installed above an oven, a
separator panel (not included) must be installed in the
compartment under the appliance.
The cross-section of wall vents and the cut-out in the
base panel should should at least correspond to the
exhaust air pipe. The outfl ow opening must be at least
500 cm². Reduce the height of the skirting boards or
make corresponding openings.
When installing the appliance make sure that the con-
vection air unit is still accessible when the kitchen has
been completely installed. If necessary levelling feet for
the kitchen units must be moved.
The hob fan can be operated in the extraction air and
recirculation air mode.
Lead the outgoing air outside through a ventilation shaft
intended for this purpose or through the wall of the
building.
Outgoing air may not be led into a smoke or exhaust
gas fl ue which is in operation. Contact the district mas-
ter chimney sweep if you are in any doubt.
A suffi cient supply of inlet air must be provided if a
wood, coal, gas or oil heater requiring a chimney is
operated in the environment of the hob fan, since an
insuffi cient supply of air results in a risk of poisoning.
The safe operation of the hob fan is guaranteed when
the negative pressure resulting from the hob fan does
not exceed 0.04 mbar (4 Pa) and a suffi cient supply of
inlet air can fl ow into the room.
Exhaust air pipes must comply with fi re class B 1 DIN
4102. Please make sure that the minimum nominal
width of the appliance connecting pieces is not re-
duced.
The Naber Compair Flow 150 system recommended
for the airfl ow and compatible with the hob extractor
should always be used.
The nominal width of the recirculation air pipe should
not be less than 150 mm.
34
Instructions for assembly
Exhaust air pipes should be as short as possible. They
should not have a 90-degree angle; instead they should
have soft bends and no reductions in their cross-secti-
on.
Never use pipes with a diameter of less than 150 mm.
No bends/ angles may be laid 50 cm before the fan
module.
Always insert a straight piece of approx. 50 cm bet-
ween two angles/bends.
Assembly
Please observe the generally valid power plant and fi re
authority requirements.
Installation/connection by qualifi ed staff members
No claims for damage caused by failure to observe
this document and/or the documents enclosed with the
appliance may be enforced against the manufacturer.
Observe minimum clearances to walls: on the side at
least 100 mm and at the back at least 50 mm.
Preparing the table cut-out
Mill around the cut-out or produce it with strips of wood.
Cut-outs accurate to dimension and right-angled.
Ensure the correct height, so that the hob and the fi lter
unit fi t exactly.
Take recess ventilation of at least 400 cm2 into account
on the side.
Units and covers must be temperature-resistant (<
75°C).
Only plan for the fi lter set to be on the left.
Installing the fan unit
Place the unit (charcoal or plasma) into the niche.
Align the air vents, fasten.
Establish an electrical connection.
Insert the hob, align.
Do not operate the hob while the silicone is hardening.
Test the primer/adhesive for usability before gluing.
Do not screw the hob tight as it weighs 18 kg (fi lter not
included).
Combustible walls/ceilings above hobs must be fi tted
with fi re-resistant cladding according to the relevant fi re
department organs.
Connecting to the electric power supply
Only switch the safety fuses/main switch on once the
hob has been installed/wired.
Mount the enclosed sign in a clearly visible position
since this will no longer be accessible after installation.
Combustible walls/ceilings above hobs must be fi tted
with fi re-resistant cladding according to the relevant fi re
department organs.
Install the hob properly to ensure its protection against
accidental contact.
The charcoal or plasma fi lter must be installed so that it
is always conveniently and easily accessible for servi-
cing purposes.
PLEASE NOTE
When the convection air mode is in operati-
on, ventilation must be suffi cient in order for
the air humidity to be removed.