Herunterladen Diese Seite drucken

Medea MCA 12 CRN1 Montage- Und Bedienungsanleitung Seite 19

Werbung

Modell: MCA-24CRN1
Kühlung
Raum -
temperatur
Total capacity kW
21ºC T
Sensitive capacity kW
15ºC F
Input kW.
Total capacity kW
24ºC T
Sensitive capacity kW
17ºC F
Input kW.
Total capacity kW
27ºC T
Sensitive capacity kW
19ºC F
Input kW.
Total capacity kW
32ºC T
Sensitive capacity kW
23ºC F
Input kW.
Aussentemperatur
21ºC
25ºC
30ºC
6.86
6.56
6.32
5.49
5.25
5.06
1.64
1.87
2.11
7.51
7.19
6.92
6.01
5.75
5.54
1.73
1.98
2.22
8.17
7.81
7.53
6.53
6.25
6.02
1.82
2.08
2.34
9.39
8.98
8.65
7.51
7.19
6.92
2.09
2.39
2.69
19
35ºC
40ºC
45ºC
5.96
5.73
5.55
4.77
4.58
4.44
2.34
2.57
2.81
6.53
6.27
6.07
5.23
5.02
4.86
2.47
2.72
2.96
7.10
6.82
6.60
5.68
5.45
5.28
2.60
2.86
3.12
8.17
7.84
7.59
6.53
6.27
6.07
2.99
3.29
3.59
50ºC
5.37
4.29
3.04
5.88
4.70
3.21
6.39
5.11
3.38
7.35
5.88
3.89

Werbung