1. FEATURES
· Length: 630 mm Closed; 1100 mm Open.
· Weight: 2,4 kg.
· Max. Pressure: 310 BAR or 4500 psi.
· Folding Base Plate
· Pump could be continuously used for more than 2 hours based on 200 BAR.
· Output nut: 1/8 BSP

2. ACCESSORY LIST

01 special spanner.
02 high pressure stem sealing ring.
03 high pressure piston ring.
04 O ring.
5 pcs
05 outer tube piston ring.
06 check valve.
07 check valve spring.
2 pcs
08 sealing gasket of bleed valve.
2 pcs
09 high pressure piston spring.
2 pcs
10 low pressure piston ring.
11 high pressure spool valve.
12 inlet hole one-way seal ball.
2 pcs
13 allen spanner.
3. INSTALL
According to the graphic, please fix the pressure gauge, output hose and 8 mm quick connector with
special spanner.
(Notice: Moderate strength can be applied but do not over tighten as this could cause the sealing ring between
the pressure gauge / hose and base plate to be deformed and jammed.) Rubber grip must be tightened and
should not be loose.
2
1 pc
2 pcs
2 pcs
2 pcs
2 pcs
2 pcs
2 pcs
1 pc
A- Rubber Grip
B- Pump Barrel
C- Base Plate
D- Pressure Gauge
E- Moisture Filter
F- Hose
G- Quick Connector
H- Test Plug
I- Bleed Valve

5. OPERATION

· It is important that you become familiar with the correct method of operation as the incorrect operation could
result in damage to the pump and possibly the user.
· Please connect the pump and container, the connector will be supplied when you buy the conainer, connecting
them according to the instruction book.
Notice: Before starting to fill the container, please read the instruction book to ensure the right way to fill the air.
· Please check the bleed valve is tightened.
When pumping the air, please be sure the hose is not knotted. Then pull and push the pump steadily. You will
begin to feel more resistance when the pressure in the container equals 100 BAR or above, this is normal.
· Please open the bleed valve screw to release the residual/excess air in the pump, barrel and hose. It is normal
to see a small amount of air and water leak from the bleed valve. You can easily remove the filler probe/valve
after releasing the air from bleed valve.
4. TEST
First of all put the test plug into 8 mm quick connectors,
open the bleed valve (bleed valve is in the back of the
base), continuously inflate gas about 20 times (correct
inflation method: rapidly upward to the head followed by a
weighty downwards press).
Second, tighten the bleed valve and pump the
pressure up to 100 BAR, then open the bleed valve quickly
to release the air. After that tighten the bleed valve again,
inflate the pressure up to 200 BAR. Check pressure gauge
to see if the needle has fallen. (If it has then air is leaking,
the best way to find the leakage point is put the pump
base, hose and test plug into water together).