INSTALLATION AND OPERATING
GB
INSTRUCTIONS
NARVI NM
NARVI MINEX
Please read the manual carefully before you start installing and using it and
keep the manual for future reference. The products are meant only to be
used as a sauna heater and for heating the sauna.
1. THE ELECTRICAL SAUNA STOVE PACKAGE INCLUDES:
1. Sauna stove jacket
2. Stone basket with control device
3. Mounting plate + anchor screws
4. Installation instructions and instructions how to use
2. BEFORE INSTALLATION:
Check the following:
-
The sauna stove is the right size (kW) for the size of the sauna (cu m).
-
Table 1 shows the volumes of the sauna for the different types of stoves.
-
If the sauna has non-insulated surfaces, for instance brick, tile or glass,
1.5 cu m must be added to the sauna volume for each square metre of
wall on the basis of which the effect needed for the sauna stove is
defined according to Table 1.
The volume values of the sauna according to Table 1 must not be
exceeded or lowered.
-
The minimum height of the sauna and the distances of the minimum
protected areas have been defined in Table 1.
-
Make sure that there is a sufficiently steady mounting plate for the
anchor screws. A thin panel alone is not enough. Additional supporting
rails behind the panel or reinforcement boards on the top of the panel
which are fastened to the wall support can be a reinforcement.
Heater
Capacity
Sauna room
model
Volume
min max
kW
m
m
3
3
NM
4,5
3
6
6
5
8
9
8
14
MINEX
2,3
1,5
2,5
3
2
3
3,6
2
4
Table 1. Installation information for heater
4,5kW
2,3kW
Minimal safety clearances to the heater
Height
on the
at the
at the
sides
front
min
A **)
B **)
mm
mm
mm
1900
50
50
1900
50
80
1900
100
100
1900
20
50
1900
20
50
1900
20
50
6kW
3kW
Quantity
of stones
to the
to the
5-10
front
ceiling
floor
C **)
D **)
E **)
mm
mm
mm
20
1150
120
20
1150
120
20
1150
120
20
900
150
20
900
150
20
900
150
**) See figure 1
*) Connected with rubber cable, type H07RN-F
or corresponding cable
9kW
3,6kW
TECHNICAL DATA
- Width
- Depth
- Height
- Weight
(without stones)
NM:
B
C
MINEX:
B
C
Figure 1. Minimal safety clearances
for the heater.
Connection *)
400 V 3N~
Fuses
230 V 1N~
cm
kg
mm
A
2
30
5x1,5
3x10
30
5x1,5
3x10
30
5x2,5
3x16
15
-
-
15
-
-
15
-
-
NM
MINEX
430 mm
330 mm
300 mm
200 mm
580 mm
630 mm
10 kg
7 kg
A
A
Connection *)
Fuses
mm
A
2
-
-
-
-
-
-
3x1,5
1x10
3x2,5
1x16
3x2,5
1x16