Safety advice:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there
is a risk of mortal injury for which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power plug must be
pulled out before changing the fuse. Defective fuses may only be
replaced with standard compliant fuses that have the same nominal
value.
4
The equipment may only be operated in dry rooms. In humid rooms
or outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4
To prevent damage to your equipment and to avoid possible
peripheral damages, the devices foreseen for wall mounting may
only be installed on a flat surface.
4
Choose the location of installation or mounting so that the power
plug can be reached and pulled out of the socket easily in case of
danger. Choose the location of installation or mounting such that
children may not play unsupervised near the equipment and its
connections. The location of installation or mounting must allow a
safe installation of all cables connected. The mains cable as well as
feeder lines may not be damaged or clamped by objects of any kind.
4
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water,
etc.).
4
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.).
Devices that are equipped with heat sinks or ventilation slots must
under no circum-stances be covered or blocked. Also ensure for a
generous air circulation around the equipment. In this way you avoid
possible damage to the equipment as well as a risk of fire caused by
overheating. Absolutely avoid that cables come near any source of
heat (e.g. radioators, other electrical devices, chimney, etc.).
State of the art 2016-06-30 - Technical changes, design modifications,
errors and misprints are subject to change without prior notice.
Technische Daten:
SKF 40-0x
Ducts
4
Receivers
4 × 8PSK/QPSK
Input
Frequency range SAT
950...2150 MHz
Level
39...84 dBµV/-70 ... -25 dBm
LNB voltage
13/17 V; 22 kHz on/off; DiSEqC 1.0
Max. LNB current (per input)
250 mA
Modulation process
8PSK/QPSK
Symbol rate
1.5...45 MS/s
Error correction
automatic
Transport stream
MPEG-2 ISO/IEC 13818
Connectors
4 × F female
Output
Frequency range
87,5...108 MHz
Modulation
FM
Terminals
1 × F plug Quickfix
General
Data interface
1 × RJ 45
Current consumption
16 V=/1.5 A
Ambient temperature range
-10°C...+50°C
Dimensions approx.
72 mm × 218 mm × 129 mm
Your device is marked with the WEEE symbol (Waste Electronics
and Electrical Equipment). This means that the electrical and
electronic components must not be disposed of as residual waste.
Used electrical and electronic components must be disposed of
WEEE Nr.
separately.
DE14023300
Manufacturer
EWR contact adress
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
SKF 40-00
8PSK/QPSK | FM
Quattro module
Quick start guide