Specific Operating Instructions
1
10,0
2
0,5
4
a.) Installation
Fastening holes (3) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall with the
connections at the bottom, see above picture, left part. For outside installation the device must also be protected against
exposure to rain and direct sunlight.
b.) Functional description of the unit
Put unit into service WITHOUT fence system. Random values are shown on the displays and the indicator lights start
flashing green or red. The values are not relevant as long as the fence system is not connected. The unit is ready for
use. If after inserting the unit no values are shown on the displays or the indicator lights do not flash, check the supply
voltage and/or the power cable. If no fault is found, have the unit checked by a technician.
c.) Functional description of the appliance with CONNECTED fence system
Display
1,1
≤3,5
≥1,1
The unit can be operated with a SEPARATE fence system connected to each fence connection (5 – 6).
If both fence outputs are used, the display (1) and the corresponding indicator apply to the maximum energy output (6).
If the indicator light flashes faster than once per second, the unit must be disconnected at once and checked by
a technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
After a delay time of 15 seconds this device is able to deliver output energy of over 5 joules. The delay time is shown in
the display (2) through the 13 pulses counting down.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore automatically
adjusts the shock strength to the increased growth, weather conditions and fence status.
If the device is operating with a lower load (more than 1000 Ohm) and the load suddenly increases so significantly that
the load resistance drops below 400 Ohm for more than 6 pulses then the device goes into an alarm mode.
The pulse interval is then extended to 3 seconds, the device issues an acoustic and visual alarm (all signal lights flash
rapidly in red).
If the load lasts more than 10 minutes then the alarm ends and the system switches back to the normal pulse frequency.
If the load drops again within 10 minutes of switching on the alarm and the load resistance thereby exceeds 600 Ohm,
the alarm is cancelled and the device resumes normal operation.
!!!Should the device be in the alarm mode, it must be switched off immediately and the fence arrangement be checked!!!
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.: 44219.
3
Mains plug used as ON / OFF!
Connection to 230 V ~!
6
5
This energizer shall not be used as an
animal trainer (inside a barn).
Output
voltage
Earth voltage
Fence NOK; output voltage ≤ 3.5 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5)
Earth NOK; voltage on earth electrode ≥ 1,1 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5);
IDEAL
6.0 – 10.0 kV; indicator
light
flashes green
0.0 kV;
indicator light
flashes green
3
NVi 9000/15000 d
Output voltage in kV
1
LCD display with
indicator light
Earth voltage in kV
2
LCD display with
indicator light
3
Fastening holes
Earth connection
4
Fence connection
5
with reduced energy
Fence connection
6
with maximum energy
OK
> 3.5 kV
(e.g. 4kV = 4000V)
indicator light flashes
green
< 1.1 kV;
indicator light flashes
green
-EN-
CHECK
3.5 kV
indicator light
flashes red
1.1 kV;
indicator light
flashes red
Version : 2016.1