Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first time.
Adhere to the safety information for the correct and safe use of the unit.
Intended use
The FP 1000, 1500, 2500, 3500 series, in the following text termed unit, is exclusively intended for pumping normal
pond water for water features and fountains. Ensure that the unit is only operated at a water temperature of
+4 °C to +35 °C and at a rated voltage coinciding with the information on the type plate.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the
case of misuse. If used for purposes other than that intended, our warranty and operating permit will become
null and void.

Safety information

Tetra has manufactured this unit to the current state of the art and the valid safety regulations. Despite of the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in
accordance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognise
possible danger or who are not familiar with these operating instructions, are not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when
passing the unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with
these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused. Only operate the unit if no persons are in the water! Prior to reaching into the water, always disconnect
the power supply to all units used in the water. Compare the electrical values of the power supply with those
on the type plate on the packaging or on the unit itself. Ensure that the unit is fused for a rated residual current
of max. 30 mA via a residual current-operating system. Only operate the unit when plugged into a correctly
fitted socket. Keep the power plug and all connection points dry! Protect the connection cable when burying to
avoid damage. Only use cables approved for outside use. Do not carry or pull the unit by the connection cable!
The power connection cable of this unit cannot be replaced. If the cable is damaged, the entire unit has to be
disposed of. Electrical installations at garden ponds must meet the international and national regulations valid
for installers. Never open the unit housing or its attendant components, unless this is explicitly mentioned in
the operating instructions. Never carry out technical changes to the unit. Only use original spare parts and
accessories for the unit. Never run the unit without water! Never use the pump for fluids other than water! For
your own safety, consult a qualified electrician when you have questions or encounter problems!
Assembly and installation (A)
Screw T distributor to the connection socket, and screw nozzle tube to the T distributor (A1). (Screw the nozzle
tube of the FP 1000 directly on the connection socket). Screw nozzle mounting and the desired water feature
nozzle to the nozzle tube (A2). It is possible to connect a hose to the lateral outlet at the T distributor by means
of the reduction element and the stepped hose connection (A3) (does not apply to FP 1000). Place the unit in
the pond horizontally on firm, sludge-free ground and ensure that it is completely covered with water (at a
maximum of 2 m below the water level).
Start-up (B)
Attention! Never operate the unit without water flowing through!
The unit switches on automatically when connection to power is established. Align the nozzle tube. The water
feature height and the water flow can be adjusted with a regulator at the lateral outlet at the T distributor (does
not apply to FP 1000). The power supply must be disconnected to switch off the unit.
Cleaning (C)
Attention! Always disconnect the power supply prior to starting cleaning and maintenance work!
Unscrew the nozzle tube including T distributor (does not apply to FP 1000) and connection socket (C1). Open
strainer casing and remove pump (C2). Unscrew pump lid and remove impeller (C3). Clean all components using
clear water and a brush. After cleaning the pump, reassemble in the reverse order. Insert pump in the strainer
casing (C). Route connection cable such that it cannot be pinched. Refit strainer lid and close (C5).
6
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for damage
and store immersed in water in a frost-free environment. Do not immerse the plug!
Wearing parts
The impeller unit including bearing and axle are wearing parts and are excluded from the warranty.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Malfunctions
Malfunction
The unit is not operating
No mains voltage
Impeller blocked/ dirty
Strainer casing clogged
Insufficient flow rate
Excessive pressure losses in the hoses
Unit switches off after a short running
Water temperature too high
period
Pond keeping information
If you have any questions regarding your pond or water garden contact Tetra at: Tetra (UK) Ltd, P.O. Box 271,
Southampton, SO18 3ZX or visit our Web Site on http://www.tetra.net

3 YEAR GUARANTEE

Tetra guarantees that this TetraPond unit will be repaired or replaced free of charge within three years from the
purchase date, if it fails due to defective materials or poor workmanship.
This guarantee does not cover normal wear and tear, nor any deterioration suffered through overloading,
improper use, negligence or accident. Similarly any modifications made by the purchaser to the appliance will
cause the guarantee to be null and void. Please keep your receipt as proof of purchase and return the enclosed
guarantee card within 14 days in order to validate your guarantee.
Cause
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Reduce hose length and connecting parts
to a minimum, route hoses as straight
as possible. Use recommended hose
diameters.
Note maximum water temperature of
+35°C