3. Install the spacers and P.C. board that are attached to the TCB-
PCNT30TLE2, on the Connection Interface Kit.
Spacers
(Attached to the
TCB-PCNT30TLE2)
4. Remove the 2P terminal block for
the communication cable of the
electric parts box on the unit, and
then replace with the attached 4P
terminal block for the
communication cable.
4-1. Disconnect the lead wires on
the 2P terminal block of the
electric parts box from the
Faston connector on the unit.
4-2. Replace the 2P connector
with 4P connector on the
terminal block.
4-3. Connect the lead wires that
are disconnected as shown
above steps 4-1, to the 4P
terminal block.
CN41
(BLUE)
(A), (B) terminals (Connecting
for the Remote Controller)
CN41
(BLUE)
5
P.C. board
(Attached to the
TCB-PCNT30TLE2)