Herunterladen Diese Seite drucken

oscartielle IDRA Betriebsanleitung Seite 15

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
Do not use adapter plugs.
The manufacturer has no liability for any damage to personnel or property caused by improper installation.
7 - Technical features
The cabinet is supplied with a plastic bag containing this manual of instructions that must be kept. It contains technical
data, wiring diagrams and tables concerning the cabinet.
The technical data are also shown on the rating plate (FIG. 3 page 3). It indicates:
1. Commercial name of the refrigerating display unit
2. Refrigerating display unit code
3. Refrigerating display unit serial number
4. Rating
5. Frequency
6. Max absorbed current
7. Max absorbed power
8. Max absorbed power during defrosting
9. Standard lighting power
10. Net display area
11. Type of cooling gas used
12. Weight of cooling gas loaded in each unit
13. Climatic class and reference temperature (dry bulb)
14. Electrical safety factor
15. Work schedule number
16. Work order number
17. Year of manufacture
Important: The rating plate and warning labels should never be removed. The manufacturer is not liable for any damages
caused by failure to respect this regulation.
This is to certify that the product complies with Legislative Decree no. 108 of 25/01/1992 applying EEC Directive 89/109
concerning materials and objects expected to come into contact with food products.
8 - Filling with products and use of the cabinet (startup)
With the cabinet off, remove the plastic film protection on the inside and outside and clean the cabinet according to the
instructions in paragraph 11.
After correctly assembling the cabinet (Par. 5), plug it into the mains (as described in Par. 6) and switch the cabinet on,
switch the light on using the switches on the control panel on the rear (FIG.10page 3). The gentle hum of the motor and
illumination of the display will indicate that the cabinet is working. The display (FIG.10 page 3) on the rear casing shows
the working temperature of the display case. The instruction manual for the electronic control to which the display refers is
enclosed with the instruction booklet (tampering with this device is impossible because a password is required and only a
specialized expert can modify it). The thermostat and gas charge are set in the factory. Tampering with the factory
settings relieves the manufacturer of any liability.
About three hours after switching the cabinet on, you can start filling it with products. Always check that the temperature
reading on the display of the electronic control is suitable for the conservation of the products placed in the display
cabinet.
The cabinet is designed for the display of food products, which are stored at the temperature of the product, and does not
lower it. The product should therefore be placed in the cabinet only after it has been chilled to its proper storage
temperature.
For better conservation of the product we recommend:
-
Do not obstruct the cold recycle vents that ensure a correct air flow.
-
Leave some room between products to ensure good air circulation.
-
When placing more products inside a partially filled cabinet, in addition to following the above instructions, it is a good
rule to place the new products underneath the existing ones.
-
Never exceed the maximum load line shown on the inside of the island (page 4, FIG.11).
9 - Prohibitions and regulations
Caution: disconnect the cabinet from the power supply in case it is not used. The power supply has to be disconnected
by the remote-control switch fitted upstream from the power socket.
Caution: do not expose the cabinet to atmospheric agents, never use jets of water to clean it, do not touch and use the
cabinet with wet or damp feet or hands.
Caution: do not remove guards or covers that require tools to remove them, never remove the cover on the power panel.
Caution: do not place heavy loads on the shelves and in the cabinet, and never climb on the counter top.
Caution: the refrigerator system does not chemically alter the defrost water produced by the cabinet in any way. This
water is condensed steam from the air that circulates inside the cabinet. In any case, the water produced by the systems
should always be drained into the sewer system or treatment plant in accordance with the laws in force.
Caution: any possible use not explicitly indicated in this manual is to be considered hazardous and the manufacturer
cannot be held responsible for any damage caused by improper, erroneous and unreasonable use of the cabinet.
Caution: Do not damage the refrigerant circuit (IEC60335-2-89:2002 and changes)
13

Werbung

loading