Herunterladen Inhalt Inhalt Diese Seite drucken

ACM WINDSUN Anweisungen Und Hinweise Für Den Installateur Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

WINDSUN
An electronic control unit integrated into the Wind/Sun Sensor compartment, for the
automation of sun blinds and rolling window shutters, with the possibility radio control
operation for individual and/or centralised control.
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
ATTENTION
Read the instructions carefully before starting to install and programme the control unit.
Follow the instructions scrupulously. Incorrect installation may create serious risks. The
manufacturer declines all liability in the event of incorrect installation or improper use of
the product.
1. CARACTERISTIQUES TECHNIQUES
- Power supply:
- Motor output:
- Working temperature:
- Anemometer sensitivity:
- Sun sensor sensitivity:
- Number of codes that may be stored:
- Packaging dimensions:
- Container:
2. CONNECTION OF CN 1 TERMINAL BOARD
1: Earth
2: 230V line input (Phase).
3: 230V line input (Neutral).
4: Upward movement motor output.
5: Shared motor output.
6: Downward movement motor output.
16
Electronic Control Unit
230V~ 50/60Hz 2,5 W
230V~ 500W Max.
-10 / 60°C
5 / 40 Km/h
5 / 40 Klux
4 Max.
240x185x110 mm.
PC UL94V-0 (IP54)