INSTALLATION
Installation
SBP 700 E | SBP 700 E SOL
8.6
Heating water connection
Note
Connect the hydraulic connections with flat gaskets.
8.6.1 Fitting the drain valve
f To facilitate maintenance work on the appliance, fit a drain
f
valve (not included in standard delivery) in the lowest con-
nection line.
8.6.2 Fitting the air vent valve
Material losses
!
Before filling the appliance, fit an air vent valve to prevent
water damage.
www.stiebel-eltron.com
8.7

Sensor installation

1
2
3
4
1
Plug
2
Sensor lead
3
Spring shackle
1
2
3
4
1
Cover sleeve
2
Plug
3
Sensor lead
4
Thermal insulation
f Plug the cover sleeve into the sensor well.
f
f Bend the temperature sensor spring shackle over forwards.
f
f Route the temperature sensor through the cover sleeve and
f
push it into the sensor well, as far as the cylinder wall.
f To secure the sensor lead, press the plug into the cover
f
sleeve as far as it will go. In doing so, route the sensor lead
downwards out of the sensor well.
Note
If no temperature sensor is being used, seal the sensor
well by pressing the plug fully into the cover sleeve to act
as a dummy plug.
SBP 200-700 E | SBP 700 E SOL |
5
4
Temperature sensor
5
Cover sleeve
6
Sensor well
5
6
7
8
5
Spring shackle
6
Temperature sensor
7
Cylinder wall
8
Sensor well
6