Herunterladen Diese Seite drucken

Installation - Panlux SV150/B Gebrauchsanweisung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
MODEL:
SV150/B
SV150/C
SV500/B
SV500/C
ENG |
INSTRUCTIONS
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should
be provided by qualified person or company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Input fuse: 6,3A/250V
Additional load: max. 850W (SV150) | 500W (SV500)
incandescent lamp
max. 250W (SV150) | 150W (SV500)
fluorescent lamp
Angle of detection: horizontal – 180°, vertical – 60°
Rotation of sensors head: horizontal - ±90°,
vertical - ±90°
Reach: max. 12m (SENS), adjustable
Recommended installation height: 2,5m
Material: metal, plastic ABS, glass
Notice
Before using, check the product and make sure there is no damage, otherwise do not use it. Before every manipulation assure
that mains electrical supply is disconnected. In case of damage do not repair or disassemble the product. For the best functional
results, move toward the sensor (see to pic. 6). The incorrect function of the product can be caused by interruption of electro-
magnetic field, small temperature difference between moving object and surroundings, reflection (e.g. strong luminous source).
Before replacing the light source switch off the light and let it cool down. Kindly use only recommended light sources
(SV150 – max.150W R7s/78mm, SV500 – max.500W R7s/118mm)
Infringement of any mentioned instruction can cause harm to health or property.

Installation

SV150
max. 150W
R7s/78mm
600g
max. 500W
R7s/118mm
SV500
1030g
26mm
35mm
225mm
285mm
ø5mm | 8mm
130mm
130mm
200mm
190mm
104mm | 138mm
1
2
230V~50Hz
26mm
ø8mm | 10mm
35mm
cable gland
52mm | 69mm
230V
~50Hz
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices
the change and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – SENS (max. 12m)
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor.
Reach can be changed by knob or with rotation of sensors head.
Time setting (switch-off delay) – TIME (10s (±5s) to 4min (±1min))
The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum
during functional test.
Twilight setting (response threshold) – LUX (2 – 2000lx)
We recommend setting the function on maximum during test.
Stated information may differ according to position and installation height.
Position marked - or  applies to minimum and position marked
If the product is mechanically damaged or connected unprofessionally, guarantee cannot be allowed.
3
4
L N
terminal block
VANA | SENSOR
SENS
R7s
IP44
or
+
5
6
180˚
60˚
12m
0,5 - 3,5m
1,8 - 2,5m
min. 200mm
min. 90°
All right reserved.
Technical data can be changed without previous notice.
LUX
TIME
3x1,5mm
C
2
applies to maximum.
7
max. 4°
max. 4°
min. 50mm
min. 1m
max. 50°
UM_VANAS_141113