Herunterladen Diese Seite drucken

Schwaiger ZHS21 Bedienungsanleitung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ZHS21
MOTION DETECTOR
USER MANUAL ZHS21
Congratulations and thank you for purchasing the Schwaiger
ZHS21 product. Below you will find useful operating guidelines.
Network inclusion of the motion detector
Put the Gateway into inclusion mode.
Remove the protective battery cover, press the networking button for 2 seconds
until the green LED starts to flash fast.
This is a smart motion detector which is based on the ZigBee Wireless Networking tech-
nology. It has a very low power consumption which makes for longer battery life. The
motion detector is only suitable for indoor use. Upon choosing a place for installation
of the detector, please make sure that the device is not exposed to extreme changes in
temperature (e.g. near a radiator) and that there are no constantly moving objects (e.g.
ceiling fan) in close proximity to the motion detector.
Network inclusion
1. Remove the protective battery cover.
The red LED will then glow. The device can be used
as soon as the red LED is off.
This takes up to 30 seconds.
2. Put the Gateway into inclusion mode
Please pay attention to the fact that during network inclusion, the distance
between motion detector and Gateway may not exceed 0.5 m.
3. Networking button
Press the networking button (within the hole) for 2
seconds until the green LED starts to flash fast, then
let go. The device will be detected and included into
the network.
MANUFACTURER INFORMATION
Dear Customer,
should you require technical advice
and your retailer could not help
please contact our technical support.
4. Installation of the motion detector
Select a place for installation. Remove the protective cover and stick the bracket to the
place desired.
5. Attach the motion detector
to the bracket
LED indicator of devices
Network inclusion
Network removal / Reset
Alarm (anti-tamper key)
Technical data
Working voltage
Static curren
Alarm current
Detecting angle
Installation height
Detecting distance
Working environment
Transmission power
Frequency range
Range
Dimension
Schwaiger GmbH
Würzburger Straße 17
90579 Langenzenn
Hotline: +49 (0) 9101 702-199
www.schwaiger.de
homeautomation@schwaiger.de
Draufsicht
Seitenansicht
Anzeige
Sensor
6. Network removal of the device
Put the Gateway into removal mode by
choosing „Home setup" in the main menu
and then click on „Add device" (See images
on the left). Then reset the device to default
settings.
7. Reset to default settings
Press the networking button for 5 seconds
until the LED starts to flash slowly.
Note: For network inclusion, the sensor must
always be in the factory state.
Press the networking button for 2
seconds until the green LED starts to flash
(two times per second)
The LED flashes 6 times
(once per second)
The red LED flashes once
DC 3 V (1xCR123A battery)
≤ 15 µA
≤ 30 mA
90°
2.1 m
8 - 10 m
-10°C ~ +50°C
<1 mW
2405-2480 MHz
about 15 m (depending on building structure)
65 x 65 x 28.5 mm