26
Finish training
1. unplug the battery pulser from the power outlet.
2. Disconnect the black (-) terminal connection cable from the negative battery terminal.
3. Disconnect the red (+) terminal connection cable from the positive battery terminal.
CharGinG phases
Step 1: Diagnosis
the battery pulser will check the battery condition.
Step 2: Full load charging (Bulk-Mode)
the battery pulser will charge the battery up to 85% capacity.
Step 3: Absorption charge
the battery pulser will charge the battery up to 85-100% capacity.
Step 4: Automatic On/Off monitor
the battery pulser monitors the battery voltage. once the battery drops to below 12.8 V,
the battery pulser will start diagnostics again. this maintains the battery's highest possi-
ble charging level.
saFety FunCtions
the charger features the following safety features to prevent damage to the charger and
the battery or the vehicle:
▪
short circuit (defective battery)
▪
incorrect connection (connected with reversed polarity)
▪
overcharging