OPERATING INSTRUCTIONS
MS-20SF FUSE FINDER
ITEM NO.: 631344

INTENDED USE

The product is only allowed to be used under the conditions and for the purpose which it
was designed for. In this respect it is particularly necessary to observe the safety guidelines,
technical data, the surrounding conditions and use in dry surroundings.
The operating safety is not guaranteed in the event of modifications or conversions.
By using the device fuses can be allocated to the respective socket rings.
The allocation of the circuit and fuse by the device is merely intended as a reference. In the
event of doubt in the electrical system, for example about whether the detected fuse has
actually interrupted the correct electrical circuit, a qualified electrician has to be consulted.
In any event, after switching off the fuse it must be ensured that the affected electrical circuit
or socket ring is disconnected by performing additional tests.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If
you use the product for purposes other than those described above, the product may be
damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric
shock etc. Read the instructions carefully and keep them. Make this product available to third
parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.

DELIVERY CONTENT

• Transmitter
• Receiver
• 9 V block battery
• Pouch
• Operating instructions

EXPLANATION OF SYMBOLS

Protection class II insulation (double or reinforced insulation)
Measurement category I for measurements on signal and control voltages without
CAT I
powerful discharges.
Measurement category II for measurements on electric devices connected to the
CAT II
mains supply by a power plug. This category also covers all smaller categories (e.g.
CAT I for measuring signal and control voltages).
Overvoltage category III for measuring in building installation (e.g. outlets or
CAT III
subdistribution). This category also covers all lower categories (e.g. CAT II for
measuring electronic devices).

SAFETY INSTRUCTIONS

Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) Persons / Product
• The product is only allowed to be used in dry indoor conditions.
• It is intended for indoor use only. Do not use it outdoors. Contact with moisture,
e.g. in bathrooms, must be avoided under all circumstances.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
VERSION 09/14
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
• The product is only allowed to be connected and operated at a safety socket.
• The mains outlet must be located near to the device and be easily accessible.
• Never pull the mains plug from the socket by pulling at the cable. Always pull it
from the mains socket using the intended grips.
• Unplug the mains plug from the mains socket if you do not use the device for an
extended period of time.
• Disconnect the mains plug from the mains socket in thunderstorms for reasons
of safety.
• Make sure that the mains cable is not squeezed, bent, damaged by sharp edges
or put under mechanical stress. Avoid excessive thermal stress on the mains
cable from extreme heat or cold. Do not modify the mains cable. Otherwise the
mains cable may be damaged. A damaged mains cable can cause a deadly
electric shock.
• Do not touch the mains cable if it is damaged. First, power down the respective
mains socket (e.g. via the respective circuit breaker) and then carefully pull the
mains plug from the mains socket. Never use the product if the mains cable is
damaged.
• A damaged mains cable may only be replaced by the manufacturer, a workshop
commissioned by the manufacturer or a similarly qualified person, so as to
prevent any danger.
• Never plug in or unplug the mains plug when your hands are wet.
• This product has been constructed in accordance with the safety provisions
for electronic measuring and test devices and left the factory in a proper safety
condition. To maintain this condition, the user has to observe the safety guidelines
in these operating instructions.
• For all work the respectively valid accident prevention regulations of the professional
associations for electrical systems and equipment have to be observed.
• To prevent the risk of electric shock, it is imperative to observe all prevailing safety
and DIN VDE regulations concerning inadmissible high contact voltage, if you are
working with voltages over 120 V (60 V) DC or 50 V (25 V) AC eff.
• Measurements made dangerously close to electrical systems are only to be
performed under the instructions of a responsible electrician and not alone.
• This product is only allowed to be used at the nominal voltages stated in the
technical data.
• If the product is exposed to an extremely high electromagnetic field, its function
may be affected.
b) (Rechargeable) batteries
• Correct polarity must be observed while inserting the (rechargeable) battery.
• The (rechargeable) battery should be removed from the device if it is not used
for a long period of time to avoid damage through leaking. Leaking or damaged
(rechargeable) batteries might cause acid burns when in contact with skin,
therefore use suitable protective gloves to handle corrupted (rechargeable)
batteries.
• (Rechargeable) batteries must be kept out of reach of children. Do not leave
(rechargeable) batteries lying around, as there is risk, that children or pets
swallow them.
• (Rechargeable) batteries must not be dismantled, short-circuited or thrown into
fire. Never recharge non-rechargeable batteries. There is a risk of explosion!
c) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical
support or another qualified specialist.