• Never pour any liquids above or next to the product. You run the risk of causing a
fire or a fatal electric shock.
If any liquid has still managed to enter the device, immediately turn off the power
supply to the mains socket at which the product is connected (turn off the fuse / cir-
cuit breaker / residual current operated circuit breaker of the associated circuits).
Only then can you unplug the mains plug of the product from the mains socket and
contact a specialist. Do not use the product anymore.
• In commercial institutions, the accident prevention regulations of the Employer's
Liability Insurance Association for Electrical Systems and Operating Facilities are
to be observed!

Getting Started

• Place the torch with the underside on a horizontal, stable, level and sufficiently large surface.
Keep all packaging parts out of the reach of children.
• Place the metal plate with the silk cloth on it into the two slits of the bracket. Let the silk cloth
hang out toward the outside.
• Switch the torch light off and connect the torch to a proper earthed socket of the public mains
using the provided mains cable.
• Switch on the torch with the power switch.
Thereupon, the LEDs light up and the fans in the torch begin to blow air out upwards. The silk
material is blown upward by the air.
If necessary, hold the silk such that it does not get into the intake openings.
• If the torch is no longer needed, switch it off and separate it from the mains voltage; pull the
plug out of the mains socket.

Fuse replacement

A small fuse is built into the torch's IEC socket. The fuse can trip in the case of an overload.
Proceed as follows to replace the fuse:
• Switch the torch off and separate it from the mains voltage; pull the IEC plug out of the torch
socket.
• Pull the fuse holder marked with a fuse symbol out of the IEC socket. If necessary, you can
use a flat screwdriver to lever the fuse holder out carefully.
• Replace the defective fuse with a new fuse of the same type (same size, same power rating,
same trigger characteristics); for data, see the chapter "Technical Data".
• Slide the fuse holder into the corresponding opening again until it clicks into place.
• Reconnect the torch to the mains voltage using the mains cable and switch it on.
• If the fuse blows again, switch the torch off and separate it from the mains voltage; pull the
IEC plug out of the torch socket.
After this, arrange for an expert to check the product.

Maintenance and Cleaning

The product is maintenance-free. Repair or maintenance work must be carried out by a special-
ist. The LED bulbs used are permanently installed; they cannot be replaced.
You can use a clean, dry, soft cloth for cleaning. Dust can be very easily removed with a soft,
clean brush and a vacuum cleaner.
Do not use aggressive, chemical or scouring cleaning agents, as this may lead to discoloura-
tion or changes in the material on the surface.
If the silk cloth needs to be cleaned, you can do this with lukewarm water and a mild detergent
suitable for silk. Then let the silk cloth dry completely before putting it into the torch again.
Disposal
The product must not be disposed of in the household waste.
Dispose of the product at the end of its serviceable life in accordance with the cur-
rent statutory requirements; e.g., return it to any suitable collection point.

Technical Information

Operating voltage .................................230 V/AC, 50 Hz
Power input ..........................................135 W
Protection class ....................................I
Operating location ................................Only in dry, enclosed indoor spaces
Ambient conditions ............................... Temperature -20 °C to +40 °C; air humidity 30% to 75%
Illuminant .............................................. 32 red LEDs, 4 blue LEDs (each permanently installed,
Torch height (silk material) ....................approx. 75 cm
Luminous flux .......................................215 lm
Fuse type .............................................. Microfuse 5 x 20 mm (Ø x L), 250 V, 5 A, fast-blow trig-
Dimensions ...........................................525 x 330 x 245 mm (W x H x D)
Weight ..................................................12 kg
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
(www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. This publication represent the technical status at the time of
printing.
© Copyright 2014 by Conrad Electronic SE.
relative, not condensing
non-replaceable), Ø 10 mm
ger characteristics (F5A)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis