Function
Capacitance (F)
Temperature (°C, °F)
1
)
Accuracy is valid for one year from the last calibration.
2
)
Overload protection: 250 V AC Effective value or 250 V DC
3
)
min. 2 A AC Effective value (Measurement via Induction clamp) or
min. 0,8 V AC Effective value (Measurement via Input terminal)

8. Operating Instructions

Always switch OFF the device when it is not in use.
If "OL" is displayed while measuring the value exceeds the used range.
Switch to a higher range if available.
Attention!
Due to the high sensitivity the reading sometimes shows random values if the
test leads are not connected to any signal. The reading stabilizes when the test
leads are connected to the circuit to be tested.
Avoid voltage measuring in electrical circuits while motors are switched on or
off. The stress-spikes can damage the instrument.
Hazardous voltage! The probes may not be long enough to touch the hot parts
in some 230V wall sockets as they are deep inside. As a result, the reading can
Range Resolution
60 nF
600 nF
2
)
60 µF
600 µF
60 mF
-20 - 1000 °C
2
)
-4 - 1832 °F
0,01nF
0,1 nF
6 µF
1 nF
10 nF
100 nF
6 mF
1 µF
10 µF
1 °C
2 °F
EN 11
Accuracy of the value
1
displayed in %
±(4,0% + 3 digits)
±(1,0% + 2 digits)
)