4. Modes & Functions:
Normal Mode.
The main measuring method of VI-D4 meter is Normal mode. In this setting the measured value is
refreshed continuously.
Max. Hold mode.
If the measured area is not easily reachable and it is impossible to read the value while measuring,
the Max. Hold mode may be used. After choosing that mode the measured value is not refreshed
continuously. The meter will show only the highest value gained from numerous measurements.
!
Caution: Even single touching of sensor plate or electrodes during this mode will cause a highly
inaccurate outcome. That in turn will result in the need of repeating the whole measurement process.
The measurement in that set may be repeated by switching the mode into Normal and then into Max.
Hold again
Auto turn-off.
In order to maximize batteries lifetime, the meter automatically turns off after 12 minutes. This
function is always active and can't be switched off.
Service Info.
This mode enables to check some meter service information which include:
This mode may be accessed by pressing and holding the SET button for 5 seconds and then by
pressing ON/HOLD button simultaneously. All the information will be shown as long as the SET
button will be held.
WOLFF | Eine Marke der Uzin Utz Gruppe | Dieselstr. 19 | D-71665 Vaihingen/Enz | Fon: +49(0)7042-9511-0 | Fax: +49(0)7042-9511-41 |
- Total working time
- Quantity of switching-on
- Software version
- Batteries voltage