Herunterladen Diese Seite drucken

axing SPU 556-09 Betriebsanleitung Seite 4

Premium-line kaskadenbausteine

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are only suitable for in-house distribution of RF signals! If the
device is used for other purposes, no warranty is given!
With the cascading units 4 SAT IF polarization levels including terrestrial
signals (e.g. FM radio) can be distributed to several SAT receivers.
SPU 556-09 = 6 receivers
SPU 558-09 = 8 receivers
SPU 5512-09 = 12 receivers
SPU 5518-09/-19 = 18 receivers.
RF-Installation:
Note: For a cascading system with the cascade units SPU 556-09, SPU 558-
09, SPU 5512-09 or SPU 5518-09/-19 you need a multiswitch SPU 56-09,
510-09 or 516-09 or a headamplifier SVS 550-09 . Please note when
installing these multiswitches or a headamplifier the appropriate operation
instructions.
4
Connect the outputs of the multiswitch to the inputs of the cascade
unit. Use F/F Quickfix adapters CFA 4-01 (not included in delivery).
Using adapters you can easily plug the devices on each other (see
figure 1 to 3).
4
If you use several cascade units, connect the outputs of the first
cascade unit to the inputs of the next cascade unit and so on. Note:
According to the dimensions of your SAT system, you may have to use
after some cascade units a further multiswitch to amplify the trunk
signals (4).
4
Terminate the outputs of the last cascade unit with the resistors CFA
11-00 you find in the carton box of the multiswitch (5).
4
Connect the receiver outputs on the left and right sides to the antenna
sockets. Use coaxial cables with F Compression connectors. Suitable
cables and connectors can be found in the current AXING catalogue or
under www.axing.com.
Mounting:
Use the included mounting screws and the mounting holes of the devices (6).
4
Important: Please make sure, that possible standards (EN 60728-11)
and safety regulations regarding electrical grounding must be kept.We
would therefore recommend to use QEW Earthing angles.
1
2
4
3
6
5

Werbung

loading

Diese Anleitung auch für:

Spu 5518-09Spu 5512-19Spu 558-09Spu 5512-09