07. Replacement Parts

Cutting elements are subject to natural wear and excluded from the
warranty. For optimal shaving a replacement in good time is essen-
tial.
You can reorder the following replacement parts under
www.aquarius-service.com or service@pepcare.de:
• Set consists of dual cutter system with cutter foil and double cutter
(Article no. 9199022).
Recommended Replacement Intervals
We highly recommend to replace shaving system annually in order
to guarantee an optimal cutting performance.
The replacement parts can be ordered via the Service Centre.

Replacing Parts

1. Take off the protective cap.
2. Press the release buttons (3) for the cutter foil frame and remove it.
3. Press the release buttons (6) for the cutter head and remove it.
4. Grasp the old cutter blades at the ends, holding them between
your thumb and index finger. Carefully remove them from the
shaver.
5. Grasp the new cutter blades at the ends, holding them between
your thumb and index finger. Place them into the cutter head. Push
the cutter blades all the way down until you hear a click.
6. Place the new cutter foil frame into the cutter head frame.
Carefully push the cutter foil frame into the cutter head frame until
you hear a click.
7. Place the cutter head back into the shaver. When replacing the
cutter head, ensure that the gap in the cutter head is point-
ed towards the long-hair trimmer on the back. Carefully push
the cutter head onto the shaver until you hear a click.
34

08. Troubleshooting

DANGER!
• Do not attempt to repair the shaver yourself.
• Always remove the wall power supply from the socket
whenever a fault occurs.
Fault:
No function
The shaving performance
diminishes
If you are experiencing a fault which is not listed here, please do not
hesitate to contact our Service Centre. Repairs must only be carried
out by specialised technicians.
Please check the following:
• Is there power coming from
the power point?
• Battery low?
• Have you cleaned and oiled
the cutting blade?
35