Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Performing A Reset; Technical Specifications - Kärcher WT 5 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für WT 5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Fault
Cause
The irrigation
Water tap is closed.
does not take
Battery depleted.
place in spite
of the pro-
Battery contacts oxidized.
gramming.
Filter gaskets blocked.
Valve does not
When the control unit is removed,
open / close.
the valve cannot open / close.
No display in-
Battery empty or contacts oxidised. Insert a new 9V battery (type
dication
Leakage at the
Filter gasket defective.
water connec-
The water connection at the water
tion.
tap has become loose.
Our Kärcher branch will be pleased to help you further in the case of questions or
faults. See address on the reverse.
 Remove the battery from the battery compartment until the indication on the
display has completely gone out.
or
 The settings are reset by pressing the OK button for 5 seconds.
Operating pressure
Max. feed temperature
Ambient temperature
Battery type
Subject to technical changes.
26 English

Troubleshooting

Performing a reset

Technical specifications

Correction
Open tap.
Insert a new 9V battery (type
6LR61).
Clean the contacts.
Clean the filter gasket.
Attach the control unit to the
valve unit.
6LR61) or clean contacts.
Replace the filter gasket.
Reconnect the water connec-
tion.
0,1 - 1,0 (1 - 10)
35
+1 -> +60
9V (6LR61 / Alkaline)
9V (size as: 6LR61 / Rechargea-
ble battery with low self-discharge
and at least 250 mAh)
MPa (bar)
°C
°C

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis