3.
Use - Cont.
3.6
Change water shut off delay time
Water shut off delay time refers to the duration of water flow from the point of time hands
are outside the detection range of the water sector. For example, water continues to flow
for (X) seconds after hands are removed from water sector.
Press the «DELAY» button. The water sector will light up. With the «+» and «-» buttons,
the water shut off delay time can be changed. To save settings, press the «SAVE»
button. All colored LED lights illuminate to indicate new setting has been saved. If
«SAVE» button is not pressed within 10 seconds of last selection, previously saved
setting will be stored.
There are 9 time settings available. Each time setting is indicated with a different beep
tone. For miscea models with a display screen, this will also be indicated visually on
screen. Please see Fig. C - E for technical data.
3.7
Change water temperature memory time
Water temperature memory time refers to the duration for which the most recently used
water temperature is temporarily stored in memory. For example, when the water
temperature is altered and the water sector is activated in quick intervals, the last used
temperature will be temporarily stored in the faucet memory for an (X) amount of time.
Press the «MEMO» button. The water sector will light up. The «+» and «-» sectors on the
faucet will light up red and blue respectively. With the «+» and «-» buttons on the remote
control, the water temperature memory time can be changed. To save settings, press the
«SAVE» button. All colored LED lights illuminate to indicate new setting has been saved.
If «SAVE» button is not pressed within 10 seconds of last selection, previously saved
setting will be stored.
There are 9 settings available. Each setting is indicated with a different beep tone. For
miscea models with a display screen, this will also be indicated visually on screen.
Please see Fig. C - E for technical data.
3.8
Change duration of bucket mode
Duration of bucket mode refers to the length of time the system remains in the bucket
mode after activation. This function is not available on all miscea models.
Press the «BUCKET» button. The water sector will light up. With the «+» and «-» buttons,
the duration of time the system remains in bucket mode can be changed. To save
settings, press the «SAVE» button. All colored LED lights illuminate to indicate new
setting has been saved. If the «SAVE» button is not pressed within 10 seconds of last
selection, previously saved setting will be stored.
There are 9 settings available. Each setting is indicated with a different beep tone.
Models with a display will also be indicated visually on screen. Please see Fig. C - E for
technical data.
12
DELAY
MEMO
BUCKET