4.

ELECTRICAL CONNECTIONS

Radar RER
Power supply
(tension/current)
230 V~ / 0,3 A
4.1 Commands
Command
1
3
N.O.
OPENING
1
4
N.O.
CLOSING
1
3
N.O.
STOP
1
4
N.C.
REVERSAL SAFETY
41
8
DEVICE
4.2 Outputs and accessories
Output
1
+
0
-
1
+
BL
-
RER
4.3 Trimmer
TC
30 s
MAX=disabled
0 s
4.4 Signals
LED (two-color)
Green
Red
4.5 Dip-Switches
Description
DIP1
Closure thrust.
Maintain the door wing in the closure position.
DIP2
Direction selection.
The opening direction is intended by viewing the
automation from the side being examined.
0 1 3 4 8 41BL
RER
TC
Function
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
The coincidence of an opening and closing command stops all movements.
Attention: when the contact opens again the door proceeds with the
interrupted manoeuvre.
The opening of the contact during the closure manoeuvre causes the
movement to invert (re-opening).
Value
Accessories power supply.
24 V= / 0,3 A
Power supply output for external accessories.
Blocking device .
Blocking is only activated when the door is closed.
24 V= / 0,5 A
Note: the door is released in the event of power failure and can be
manually operated.
RER Radar. Allows the connection of one or two RER radar.
Attention: set the radar dip/switch RER=DX.
Automatic closing time. From 0 to 30 s. Adjust the time that passes between the end
of the opening manoeuvre and the start of the automatic closing manoeuvre. The count
is reset when an opening command is given with the door open. Adjust the TC to the
maximum if automatic closing is not required.
ON
24 V= power supply.
Safety contact 41 - 8 open.
Disabled.
Left-hand opening for single door
wing automations.
Selection for double door wing
automations.
-
+ Output 24 V= / 0,3 A
Opening
Closing
Re-openin g
Electric lock
LED
ON
1 2
Description
Description
Encoder/automation fault.
Safety test failure.
OFF
Enabled.
Right-hand opening for single
door wing automations
Flashing
ON
15/44