Herunterladen Diese Seite drucken

axing SES 544-06 Betriebsanleitung Seite 4

Premium-line einkabelmultischalter

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are only suitable for distributing radio and television signals inside
the house! If a device is used for other purposes, no warranty is given!
Scope of delivery:
1 × Single cable multiswitch II (SCR)
1 × Operation instructions
Outputs and preset user bands:
There are 4 user bands (acc. EN 50494) available at each of the 4 subscriber
ports:
UB1: 1331 MHz
UB2: 1382 MHz
UB3: 1433 MHz
UB4: 1484 MHz
Connectors, switches, mounting angles:
1
SAT inputs for LNB
LV, LH, HV and HH for Quattro LNB
LV and LH for 1st Wideband LNB
HV and HH for 2nd Wideband LNB
2
TERR input
3
Equipotential bonding connection
4
Subscriber ports
5
DC connector for power supply SZU 99-06
6
SAT cascade outputs
7
TERR cascade output
8
Mounting angles
9
Wideband-Quattro switch
10 Legacy-CSS switches
9
4
10
Equipotential bonding and mounting:
To avoid dangerous power surges (e.g. risk of fire and danger of life) the device
must be connected to the equipotential bonding according to EN 60728-11.
 Use the equipotential bonding connection at the device (3).
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. QEW Earthing angles at the inputs and outputs of the
device.
 Use appropriate mounting screws for the mounting angles of the device (8).
Quattro LNB:
RF installation:
 Connect the SAT inputs (1) of the multiswitch to the LNBs of your SAT
reception antenna. Connect the output signals of a terrestrial amplifier or a
CATV amplifier to the terrestrial input (2).
1
2
 Connect the subscriber outputs (4) of the multiswitch to the antenna
sockets. Use highly shielded coaxial cables with F connectors. Suitable
cables and connectors can be found in the current AXING catalogue or
under www.axing.com.
 If you don´t use cascade units to expand the multiswitch, terminate
5
the outputs (6 + 7) on the lower side with termination resistors
CFA 11-00 (not included in delivery).
Legacy mode
3
 Each output can be switched to legacy mode separately. The output then
behaves as a normal multiswitch output. This allows to connect receivers
which don´t support CSS/SCR.
Legacy mode can not be used with wideband LNBs!
8
6
7
CSS/SCR
Legacy
CSS/SCR
Legacy
Wideband-LNB:
 The single cable multiswitch is wideband capable.
 Slide the sliding switch (9) to W = Wideband.
 Connect the first wideband LNB to the connectors LV and LH and the
second wideband LNB to the connectors HV and HH.
Power supply:
If one Quattro LNB is used, the SES 544-06 and the LNB can be fed from the
connected receivers.
If wideband LNBs are connected, a power supply unit SZU 99-06 is
required (not included in delivery).
 Connect the power supply unit to the DC socket (5) using the enclosed
cable.
 Plug the power supply into an electrical outlet.
 The green power LED is lit.
Cascading:
Up to three single cable multiswitches can be connected to one cascade.
 Connect the outputs of the single cable multiswitch with the inputs of
the next single cable multiswitch units.
 Use F/F Quickfix adapters CFA 4-01 (not included in delivery).
 Terminate the outputs of the last single cable multiswitch with resistors
CFA 11-00 (not included in delivery).

Werbung