Safety advices:
 Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
 Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
 Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
 Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
 The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
 To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
 Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
 Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
 Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
State of the art 2018-04-11
Technical improvements, changes in design, printing- and other errors expected.
Technical data:
Frequency range TERR
Frequency range SAT (quattro LNB | wideband LNB)
Input level (AGC)
Inputs
Subscriber ports
User bands
User band frequencies
Standards
Tap loss TERR
Output level SAT @ 60...90 dBµV input level
Through loss TERR
Through loss SAT
Isolation H/V
Return loss (inputs/outputs)
Ambient temperature range (acc. to EN 60065)
Connectors
LNB supply voltage
Max. LNB supply current (total | per LNB)
Current consumption from STB (SCR/CSS)
Equipotential bonding connection
Dimensions (W × H × D) appr.
1
all 4 user bands are available at both outputs
You can call up the complete EU declaration of conformity for download by
entering the part number in the search field at www.axing.com.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.
Manufacturer
EEA contact address
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
5...862 MHz
950...2150 MHz | 250...2350 MHz
60... 90 dBµV
5
2
SES 522-06
4
1
1331/1382/1433/1484 MHz
premium-line
EN 50494, EN 50607
17 dB
82 dBµV ±2,0 dB
Single cable multiswitch II (SCR)
2 dB ±2,0 dB
2 dB ±2,0 dB
Operation instructions
30 dB
≥ 10 dB
-20...70°C
F
12 V
1000 mA | 500 mA
180 mA
4 mm
2
140 x 111 x 63 mm