CLEANING OF THE CONDENSER: (Picture 7)
1 Unplug the cabinet.
2 Remove the compressor housing grid (Picture 6/1b)
3 Clean the condenser with a brush, an air jet or a vacuum cleaner in order to avoid
damaging the cabinet.
4 Reassemble the protection grid.
5 Plug the cabinet in.
The cabinet is not equipped with automatic defrost system. It must be manually
●
defrosted when the frost completely covers the inner shelves.
DEFROSTING:
1 Unplug the cabinet.
2 Take the product out and put it in another working cabinet.
3 Remove the plug D (Picture 6), the front grid G, plase the tube E so that the water
flows in a container and let the inner ice melt.
4 Dry the inside of the storage tank with sponge and a soft cloth.
5 Place the plug D, the tube E and the grid D again.
6 Plug the cabinet in.
7 Wait for the cabinet to reach the operating temperature before introducing the
product again.
EVERY TWO YEARS
Get the cabinet checked by skilled technical staff to make sure:
●
- the inner components are clean.
- the electric system of the cabinet is not cut-off.
- the cabinet works properly (Thermic performance).
It is advisable to get a written declaration about the good working order of the
cabinet.
The replacement of the feeding cable is to be carried out by skilled technical staff,
●
using a cable with a minimum wire section 3 x 1,5 mm .
The wiring diagram is placed on the back of the cabinet.
●
If the cabinet shows working problems, it is advisable to check if:
●
- the plug is well connected to the socket and the electric power is on.
- the general switch is the ON position
- the thermostat knob is not in the OFF position or on minimum.
After these inspections, if the problem persists, ask to the Service Center for assistance.