CAUTION! HIGH VOLUME LEVELS WITH AUDIO PRODUCTS!
This equipment is intended for professional use. Therefore, commercial use of this equipment is subject to the
respectively applicable national accident prevention rules and regulations. As a manufacturer, Adam Hall is
obligated to notify you formally about the existence of potential health risks.
Hearing damage due to high volume and prolonged exposure: When in use, this product is capable of produc-
ing high sound-pressure levels (SPL) that can lead to irreversible hearing damage in performers, employees,
and audience members. For this reason, avoid prolonged exposure to volumes in excess of 90 dB.
CAUTION! IMPORTANT INFORMATION ABOUT LIGHTING PRODUCTS
1.
Do not look into the beam from a distance of less than 40 cm.
2.
Do not stare into the beam for extended periods at short-to-medium distances.
3.
Do not view the beam directly with optical instruments such as magnifiers.
4.
Under some circumstances, stroboscopic effects may trigger epileptic seizures in sensitive individuals!
For this reason, persons who suffer from epilepsy should always avoid places where strobe lights are
used.
8
CONNECTION
The 4 independent channels of the PAN03PASS (A, B, C, and D) provide identical features.
Line level signals such as keyboard signals are fed to the INPUT using a shielded instrument cable (6.3mm
TS). For simultaneous connection to an instrument amplifier use the LINK output which is wired in parallel.
CAUTION - DO NOT USE THE LINK CONNECTOR FOR SIGNAL INPUT! ALL UNBALANCED INSTRUMENT CABLES
SHOULD BE AS SHORT AS POSSIBLE, AND THE PAN03PASS SHOULD BE LOCATED CLOSE TO THE UNBAL-
ANCED SOURCE.
The balanced lo-Z output signal is available at both the front and rear male XLR connectors. These are wired
to the international standard (pin 2 = hot) and electrically connected in parallel. The front and rear XLR ouputs
can also be used for signal splitting, however, simultaneous use with extreme lo-Z loads may result in some
loss of level.
Use shielded balanced microphone cable for connection to a mixing console input. Cable length is basically
uncritical with no audible signal degradation at 100 meters and beyond (300' +).
30DB PAD AND GND LIFT SWITCHES
The PAN03PASS can also be used to feed loudspeaker level signals to a mixing console by connecting the
amplifier output to a PAN03PASS channel INPUT, and the corresponding LINK output to a loudspeaker. Use
dedicated loudspeaker cable only for both connections (16AWG minimum). Due to the much higher
level of loudspeaker signals (compared to instrument and line level signals) the PAD 30dB switch must
be engaged. To prevent clipping the amplifier should not be rated higher than 100W.
9