Auto Mode
In this mode, automatic program flow can be set.
Sound Control Mode
In this mode, sound control mode can be set.
Slave Mode
In this mode, you can select and set the slave devices.

DMX-CONTROLLED OPERATION

You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.

Addressing the Device

Controlling:
After having addressed the LED Bar RGB 252/10 Indoor, you may now start operating it via your lighting
controller.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
Set DIP-Swich 9 and 10 to OFF.
Set DIP-Swiches 1 through 4 to OFF.
Speed can be controlled by setting the DIP-Swiches 5 and 6.
Flash can be controlled by setting the DIP-Swiches 7 and 8.
Set DIP-Swich 9 to ON and 10 to OFF.
Sensitivity can be controlled by setting DIP-Swiches 1 through 4.
Set DIP-Switch 10 to ON in order to determine the Slave device.
DIP-Swiches 1 – 9 are on OFF.
Set the DIP-Switch 10 to ON.
Set the DMX Addresses via DIP-Switches 1 through 9.