Setting the output duration for timer operation
Press the
button
buttons UP and DOWN to adjust the duration of the fog outputs in timer mode within the
range of 1 and 200 seconds.
Setting the fog output volume for timer operation
Press the
button
FUNCTION until the display indicates »Timer Out«. Use the buttons
UP and DOWN to adjust the fog output volume in timer mode within the range of 1 %
and 100 %.
Setting the fog output volume for continuous operation
Press the button FUNCTION until the display indicates »Volume Out«. Use the
Ÿ
buttons UP and DOWN to adjust the fog output volume in continuous mode within the
range of 1 % and 100 %.
To set the unit to continuous fog output, select »NON STOP BURST« below a value of
Ÿ
1 % or above a value of 100 %.
Setting the DMX 512 address
Press the FUNCTION until the display indicates »DMX 512 Add.« Use the buttons UP
and DOWN, to set the machine to the same address as on your DMX controller. Please
refer to the user manual of your fog machine for more DMX setting information.
Setting the RF address
To establish the signal transmission between the receiving unit and the transmitter, the
receiving unit must be set to the transmitter's RF address [Radio Frequency address].
For this purpose, press the button FUNCTION until the display indicates »RF ADDR«.
Use the buttons UP and DOWN, to select an RF address between 0 and 8.
-Continuous operation
Press the button VOLUME, to activate continuos fog output. The display indicates
»Volume« followed by the value that was set in menu item »Volume Out« or »NON STOP
BURST« when continuous fog output was selected. To stop the fog output, press the
button VOLUME once again.
-Manual operation
For immediate fog output at the maximum volume of fog, keep the button MANUAL
pressed. The display indicates »Manual 100 %«. As soon as you release the button, the
fog output will stop. The manual operation will take priority over the
and the timer operation. Even if one of these operating modes is activated, the fog machine
will always emit the maximum volume of fog when the button MANUAL is pressed.
-Timer operation
In the timer mode, the fog machine will automatically emit fog. The time intervals, duration
and fog volume depend on the corresponding menu settings. Press the button TIMER, to
activate the timer mode. The display indicates the set time interval. The unit counts down to
0 seconds and emits fog. To deactivate the timer mode, press the button TIMER again.
FUNCTION until the display indicates »Duration Set«. Use the
continuos
operation