Step 2
Mark the 4 drill positions by using the dimensions of the drawing on top of this page. Please note the orientation of the heater.
Using a water-level is recommended.
Tip: Before drilling the holes please check if tubes or wires are present in this area. Use a suitable metal detector.
Step 3
Drill the 4 holes by using a Ø8mm drill (depth=length of the dowel).
The depth of the holes should not differ much from the dowel length.
To ensure this demand please mark the drill or use a depth stop.
Tip: To avoid the formation of dust it is recommended to use a vacuum cleaner
simultanously.
Step 4
Push the dowels in the holes and screw the screws in.
Step 5
Fix the 4 holders with hexagon screws on the heater backside so that they are still turnable. The mouths of the holders should be
orientated in ground direction. Hang the heater to the 4 wall screws.
Turn 1 of the bottom holders 90° or 180° and use a suitable wrench to fix the srews on the heater backside. Now the heater is
fixed on the wall. Don't use other screws than the delivered ones for longer screws will damage the heating element!
Important: Although the infrared panel heater is equipped with a good thermal insulation there will be higher tempertures also on the
backside of the panel. If the heater is too close to the wall or ceiling there could be a heat accumulation on the back. The mounting
distance must not be underrun. An continual airflow behind the heater should be guaranteed.