SonicWall™ SuperMassive 9200,
9400, and 9600 DC Power Supply
Conversion and Replacement
Installation Guide
Regulatory Model Numbers:
DP1S‐2300V/ZIPPY TECHNOLOGY CORP
This DC power supply module is for use only with the SonicWall appliances indicated
below. Use of this module with a SonicWall appliance that is not approved will void the
warranty for that appliance. This module is provided as a replacement power supply, and
is provided on an "as is" basis without warranty of any kind.
This power supply (01‐SSC‐3875) is approved for use with:
SuperMassive 9200 (01‐SSC‐3810)
SuperMassive 9400 (01‐SSC‐3800)
SuperMassive 9600 (01‐SSC‐3880)
For information and related documents, see https://www.sonicwall.com/support.
Copyright ©
2017 SonicWall Inc. All rights reserved.
SonicWall is a trademark or registered trademark of SonicWall Inc. and/or its affiliates in
the U.S.A. and/or other countries. All other trademarks are property of their respective
owners.
The information in this document is provided in connection with SonicWall Inc. and/or its
affiliates' products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document. SonicWall Inc. and/or its affiliates
do not make any commitment to update the information contained in this document. For
more information, visit http://www.sonicwall.com/legal.
Legend
WARNING: A WARNING icon indicates a potential for property damage,
personal injury, or death.
CAUTION: A CAUTION icon indicates potential damage to hardware or loss of
data if instructions are not followed.
IMPORTANT, NOTE, TIP, MOBILE, or VIDEO: An information icon indicates
supporting information.
SuperMassive 9200, 9400, and 9600 DC Power Supply Installation Guide
Updated ‐ October 2017
232‐004056‐50 Rev A
1
SonicWall SuperMassive 9200, 9400, and
9600 DC Power Supply Conversion and
Replacement
The SonicWall SuperMassive 9200, 9400, and 9600 is shipped in an
AC mains configuration with standard three conductor appliance
couplers and an AC power cord. This document provides instructions
for converting AC to DC and for replacing a defective DC power
supply in your SM 9200, 9400, or 9600 network security appliance.
The DC mains cable is different and is supplied with the DC power
supply. The DC mains connector uses terminal posts with the
polarity marked.
WARNING: Do not connect an AC configured product to a DC
mains, and do not connect a DC configured product to AC. The
SonicWall SuperMassive 9200, 9400, and 9600 must be configured
as either all DC or all AC. Do not mix AC and DC power supplies in
the same chassis.
Prerequisites
• Read all Safety and Regulatory Information in the SonicWall
SuperMassive 9200, 9400, and 9600 Getting Started Guide
provided with your SM 9200, 9400, or 9600. Those
requirements still apply with a DC conversion.
• To disconnect the DC power, an external, properly‐rated,
disconnect device must be provided by the building or the
rack installation. The disconnect device must be readily
accessible.
3 Return the fan retaining bracket across the fan module and
tighten the retaining screw to securely fasten the bracket.
4 Connect the supplied DC power cable to DC mains and ground.
• Black (RTN)
• Yellow (‐48)
• Green/Yellow to ground screw next to terminal block).
• A suitably‐rated and approved DC circuit breaker should be
provided as part of the building installation. Follow local code
when purchasing materials or components.
• Reliable grounding of rack‐mounted equipment must be
maintained.
• Overcurrent Protection: This equipment shall be provided
with a suitably Listed DC circuit breaker or a Listed DC fuse, in
the building installation supply circuit.
• DC rating includes tolerances. Do not operate the product
outside of the ranges shown on the product label.
Removing the Power Supply from the Appliance
When converting from AC to DC power, both AC power supplies
must be replaced.
To remove an AC or DC power supply:
1 For an appliance with AC power supplies, remove both AC power
cords.
WARNING: The appliance must be completely powered off.
2 To replace a defective DC power supply, remove any external
power sources from the power supply module that is being
replaced.
3 Loosen the retaining thumbscrew of the #3 fan module with your
fingers or a Phillips (cross) screwdriver if necessary. Open the
fan's arm to expose the power supply's locking mechanism.
5 Apply the new label provided with the DC power supply kit over
the AC label as shown in the following image.
6 Turn on the appliance. Confirm that the new power supply is
operating correctly. On the front panel, the LED indicator for the
power supply should display a blue light. A yellow light indicates a
problem. Powering up instructions are also provided in the
SonicWall SuperMassive 9200/9400/9600 Getting Started Guide.
WARNING: Power supply surfaces can be hot. Handle and store
with care until the surfaces are cool.
4 Taking note of the power supply orientation as it relates to the
appliance, suppress the power supply release tab while using the
module's handle to pull the module outwards to remove it.
5 If converting from AC to DC, repeat this procedure to remove the
second AC power supply.
Installing a DC Power Supply into the Appliance
WARNING: Do NOT insert anything except the SuperMassive 9200,
9400, and 9600 DC Power Supply into the appliance.
To install a new SuperMassive 9200, 9400, or 9600 DC Power
Supply:
1 Insert the new power supply module using the orientation you
noted when you removed the AC or defective module, pushing
the power supply module in firmly until it is completely seated
and snaps into place.
2 Replace the metal locking mechanism arm and secure it with its
retaining screws.
2
SonicWall SuperMassive 9200, 9400, oder 9600 ‐
Umwandlung der Gleichstrom‐versorgung und
Austausch des Netzteils
Der SonicWall SuperMassive ist mit einer
Wechselstromkonfiguration mit drei standardmäßigen
Leiterkopplern und einem Wechselstromkabel ausgestattet. Dieses
Dokument enthält Anweisungen für die Umwandlung von
Wechselstrom in Gleichstrom und für den Austausch eines defekten
Gleichstromnetzteils in Ihrer SM 9200, 9400, oder 9600 Network
Security Appliance.
Das Gleichstromkabel unterscheidet sich und wird mit dem
Gleichstromnetzteil bereitgestellt. Der Gleichstromstecker
verwendet Polklemmen mit gekennzeichneter Polarität.
Warnung: Schließen Sie kein für Wechselstrom konfiguriertes
Produkt an ein Gleichstromnetz an und schließen Sie kein für
Gleichstrom konfiguriertes Produkt an ein Wechselstromnetz
an. Der SonicWall SuperMassive muss entweder vollständig
für Gleichstrom oder vollständig für Wechselstrom
konfiguriert sein. Vermischen Sie keine Wechselstrom‐ und
Gleichstromversorgungen am gleichen Gehäuse.
Voraussetzungen
• Lesen Sie alle Sicherheits‐ und Regulierungsinformationen im
SonicWall SuperMassive 9200/9400/9600
Installationshandbuch, das Ihrer SM 9200, 9400, oder 9600
beiliegt. Diese Anforderungen gelten ebenfalls für eine
Gleichstromumwandlung.
• Zur Trennung des Gleichstroms muss eine externe,
ordnungsgemäß abgesicherte Trennvorrichtung verwendet
werden, die durch die Gebäude‐ oder Rack‐Installation
bereitgestellt wird. Die Trennvorrichtung muss gut zugänglich
sein.