Regulatory Model Numbers: 
DP1S‐2300V/ZIPPY TECHNOLOGY CORP
This DC power supply module is for use only with the SonicWall appliances indicated 
below. Use of this module with a SonicWall appliance that is not approved will void the 
warranty for that appliance. This module is provided as a replacement power supply, and 
is provided on an "as is" basis without warranty of any kind. 
This power supply (01‐SSC‐3875) is approved for use with:
SuperMassive 9200 (01‐SSC‐3810)
SuperMassive 9400 (01‐SSC‐3800)
SuperMassive 9600 (01‐SSC‐3880)
For information and related documents, see https://www.sonicwall.com/support.
 
Copyright ©
2017 SonicWall Inc. All rights reserved.
SonicWall is a trademark or registered trademark of SonicWall Inc. and/or its affiliates in 
the U.S.A. and/or other countries. All other trademarks are property of their respective 
owners.
The information in this document is provided in connection with SonicWall Inc. and/or its 
affiliates' products. No license, express or implied, by estoppel or otherwise, to any 
intellectual property right is granted by this document. SonicWall Inc. and/or its affiliates 
do not make any commitment to update the information contained in this document. For 
more information, visit http://www.sonicwall.com/legal.
Legend
WARNING: A WARNING icon indicates a potential for property damage, 
personal injury, or death.
CAUTION: A CAUTION icon indicates potential damage to hardware or loss of 
data if instructions are not followed.
IMPORTANT, NOTE, TIP, MOBILE, or VIDEO: An information icon indicates 
supporting information.
SuperMassive 9200, 9400, and 9600 DC Power Supply Installation Guide
Updated ‐ October 2017
232‐004056‐50 Rev A
     1 
SonicWall SuperMassive 9200, 9400, and 
9600 DC Power Supply Conversion and 
Replacement
The SonicWall SuperMassive 9200, 9400, and 9600 is shipped in an 
AC mains configuration with standard three conductor appliance 
couplers and an AC power cord. This document provides instructions 
for converting AC to DC and for replacing a defective DC power 
supply in your SM 9200, 9400, or 9600 network security appliance.
The DC mains cable is different and is supplied with the DC power 
supply. The DC mains connector uses terminal posts with the 
polarity marked.
WARNING: Do not connect an AC configured product to a DC 
mains, and do not connect a DC configured product to AC. The 
SonicWall SuperMassive 9200, 9400, and 9600 must be configured 
as either all DC or all AC. Do not mix AC and DC power supplies in 
the same chassis.
Prerequisites
• Read all Safety and Regulatory Information in the SonicWall 
SuperMassive 9200, 9400, and 9600 Getting Started Guide 
provided with your SM 9200, 9400, or 9600. Those 
requirements still apply with a DC conversion.
• To disconnect the DC power, an external, properly‐rated, 
disconnect device must be provided by the building or the 
rack installation. The disconnect device must be readily 
accessible.
3 Return the fan retaining bracket across the fan module and 
tighten the retaining screw to securely fasten the bracket.
4 Connect the supplied DC power cable to DC mains and ground. 
• Black (RTN)
• Yellow (‐48)
• Green/Yellow to ground screw next to terminal block).
• A suitably‐rated and approved DC circuit breaker should be 
provided as part of the building installation. Follow local code 
when purchasing materials or components.
• Reliable grounding of rack‐mounted equipment must be 
maintained.
• Overcurrent Protection: This equipment shall be provided 
with a suitably Listed DC circuit breaker or a Listed DC fuse, in 
the building installation supply circuit.
• DC rating includes tolerances. Do not operate the product 
outside of the ranges shown on the product label.
Removing the Power Supply from the Appliance
When converting from AC to DC power, both AC power supplies 
must be replaced.
To remove an AC or DC power supply:
1 For an appliance with AC power supplies, remove both AC power 
cords.
WARNING: The appliance must be completely powered off.
2 To replace a defective DC power supply, remove any external 
power sources from the power supply module that is being 
replaced.
3 Loosen the retaining thumbscrew of the #3 fan module with your 
fingers or a Phillips (cross) screwdriver if necessary. Open the 
fan's arm to expose the power supply's locking mechanism.
5 Apply the new label provided with the DC power supply kit over 
the AC label as shown in the following image.
6 Turn on the appliance. Confirm that the new power supply is 
operating correctly. On the front panel, the LED indicator for the 
power supply should display a blue light. A yellow light indicates a 
problem. Powering up instructions are also provided in the 
SonicWall SuperMassive 9200/9400/9600 Getting Started Guide.
WARNING: Power supply surfaces can be hot. Handle and store 
with care until the surfaces are cool.
4 Taking note of the power supply orientation as it relates to the 
appliance, suppress the power supply release tab while using the 
module's handle to pull the module outwards to remove it.
5 If converting from AC to DC, repeat this procedure to remove the 
second AC power supply.
Installing a DC Power Supply into the Appliance
WARNING: Do NOT insert anything except the SuperMassive 9200, 
9400, and 9600 DC Power Supply into the appliance.
To install a new SuperMassive 9200, 9400, or 9600 DC Power 
Supply:
1 Insert the new power supply module using the orientation you 
noted when you removed the AC or defective module, pushing 
the power supply module in firmly until it is completely seated 
and snaps into place.
2 Replace the metal locking mechanism arm and secure it with its 
retaining screws.
     2 
SonicWall SuperMassive 9200, 9400, oder 9600 ‐ 
Umwandlung der Gleichstrom‐versorgung und 
Austausch des Netzteils
Der SonicWall SuperMassive ist mit einer 
Wechselstromkonfiguration mit drei standardmäßigen 
Leiterkopplern und einem Wechselstromkabel ausgestattet. Dieses 
Dokument enthält Anweisungen für die Umwandlung von 
Wechselstrom in Gleichstrom und für den Austausch eines defekten 
Gleichstromnetzteils in Ihrer SM 9200, 9400, oder 9600 Network 
Security Appliance.
Das Gleichstromkabel unterscheidet sich und wird mit dem 
Gleichstromnetzteil bereitgestellt. Der Gleichstromstecker 
verwendet Polklemmen mit gekennzeichneter Polarität.
Warnung: Schließen Sie kein für Wechselstrom konfiguriertes 
Produkt an ein Gleichstromnetz an und schließen Sie kein für 
Gleichstrom konfiguriertes Produkt an ein Wechselstromnetz 
an. Der SonicWall SuperMassive muss entweder vollständig 
für Gleichstrom oder vollständig für Wechselstrom 
konfiguriert sein. Vermischen Sie keine Wechselstrom‐ und 
Gleichstromversorgungen am gleichen Gehäuse.
Voraussetzungen
• Lesen Sie alle Sicherheits‐ und Regulierungsinformationen im 
SonicWall SuperMassive 9200/9400/9600 
Installationshandbuch, das Ihrer SM 9200, 9400, oder 9600 
beiliegt. Diese Anforderungen gelten ebenfalls für eine 
Gleichstromumwandlung.
• Zur Trennung des Gleichstroms muss eine externe, 
ordnungsgemäß abgesicherte Trennvorrichtung verwendet 
werden, die durch die Gebäude‐ oder Rack‐Installation 
bereitgestellt wird. Die Trennvorrichtung muss gut zugänglich 
sein.
  
loading

Inhaltszusammenfassung für SonicWALL SuperMassive 9400

  • Seite 1 When converting from AC to DC power, both AC power supplies  module’s handle to pull the module outwards to remove it. mains, and do not connect a DC configured product to AC. The  must be replaced. SonicWall SuperMassive 9200, 9400, and 9600 must be configured  5 If converting from AC to DC, repeat this procedure to remove the  To remove an AC or DC power supply: as either all DC or all AC. Do not mix AC and DC power supplies in  second AC power supply. the same chassis. 1 For an appliance with AC power supplies, remove both AC power  cords. Installing a DC Power Supply into the Appliance Prerequisites WARNING: The appliance must be completely powered off. WARNING: Do NOT insert anything except the SuperMassive 9200,  • Read all Safety and Regulatory Information in the SonicWall  2 To replace a defective DC power supply, remove any external  9400, and 9600 DC Power Supply into the appliance. SuperMassive 9200, 9400, and 9600 Getting Started Guide  power sources from the power supply module that is being  provided with your SM 9200, 9400, or 9600. Those  To install a new SuperMassive 9200, 9400, or 9600 DC Power  replaced. Regulatory Model Numbers:  requirements still apply with a DC conversion. Supply: DP1S‐2300V/ZIPPY TECHNOLOGY CORP 3 Loosen the retaining thumbscrew of the #3 fan module with your  • To disconnect the DC power, an external, properly‐rated,  1 Insert the new power supply module using the orientation you  fingers or a Phillips (cross) screwdriver if necessary. Open the  disconnect device must be provided by the building or the ...
  • Seite 2 す。 切断装置にはす ぐ にア ク セスで き る よ う に し て く だ さ に光っ ているはずです。 黄色に光っ ている場合は問題が起き て い。 います。 『SonicWall SuperMassive 9200, 9400, 9600 導入ガ イ ド 』 には、 電源投入時の手順も記載 さ れています。 • 適切に評価 さ れて認定 さ れた DC 回路ブ レー カ ーが建物の設...

Diese Anleitung auch für:

Supermassive 9600Supermassive 9200