Warning!
For GROUP II applications ONLY, the user shall not carry more than a
maximum of 2 spare Duracell Plus MN1500 or Duracell Procell MN1500
cells into the hazardous area. Precautions shall be taken to prevent short
circuiting of un-protected cell terminals. Discharged cells shall be
removed from the hazardous area.
Warning!
For Class 1 Division 1 applications ONLY, the user shall not carry more
than a maximum of 2 spare Duracell Plus MN1500, Duracell Procell
MN1500/PC1500 or Energizer E91 cells into the hazardous area.
Precautions shall be taken to prevent short circuiting of un-protected
cell terminals. Discharged cells shall be removed from the hazardous
area.
Warning!
For GROUP II applications ONLY the rated ambient temperature range of
the equipment is from -20
Warning!
For GROUP I applications ONLY the rated ambient temperature range of
the equipment is from 0
Warning!
For Class 1 Division 1 applications ONLY the rated ambient temperature
range of the equipment is from -20
cells used (see Table 1).
Warning!
If any damage to the iCAM501U is found which may invalidate the
required safety minimum IP rating (IP54 for group I applications), (IP20
for group II and class 1 division 1 applications), the iCAM501U shall be
removed from the hazardous area.
Important
Any repairs or replacement of parts MUST be performed by the
manufacturer or its nominated sub contractor or agent.
Important
The iCAM501U contains no user serviceable parts. The main part of the
enclosure must not be opened under any circumstances.
Application
Duracell Plus
MN1500
OK, T4 at 60
ATEX GROUP
II
ATEX GROUP
OK, T4 at 60
I
OK, T4 at 55
CLASS 1
DIVISION 1
Operating Manual
o
o
C to 60
C.
o
o
C to 60
C.
Duracell
Procell
MN1500
o
o
C OK, T4 at 60
C
o
o
C OK, T4 at 60
C
o
o
C OK, T4 at 55
C OK, T3C at
Table 1 iCAM501U cell usage table
5
o
o
o
C to 55
C/50
C dependent on the
Duracell
Procell
PC1500
CANNOT BE
USED
CANNOT BE
USED
o
50
C
Energizer E91
CANNOT BE
USED
CANNOT BE
USED
OK, T3C at
o
50
C