1 Safety Instructions
The device shall only be
used for its intended pur-
pose and in undamaged
and perfect condition!
Only genuine CEAG spare
parts may be used for re-
placement and repair!
When working on the emer-
gency luminaire make sure
that it is disconnected from
the voltage! Pay attention to
the different power supplies
in mains or battery opera-
tion. Fig. 5 shows the
indication label on the
emergency luminaire.
Carry out the marking of the
emergency luminaire: As-
sign the circuit and the
luminaire No. and enter them.
Log book records shall be
kept in compliance with the
national regulations.
Any foreign matter shall be
removed from the luminaire
prior to its initial operation!
While undertaking any
servicing on the luminaire,
the national safety rules
and regulations for pre-
vention of accidents shall
be observed as well as the
safety instructions included
in these operating instruc-
tions marked with a
2 Conformity with
standards
Conforming to: EN 60 598-1, EN
60 598-2-22, EN 1838, DIN VDE
4844 and IEC 60 924 as well as
IEC 60 928. Designed,
manufactured and tested
according to DIN EN ISO 9001.
Fig. 5
3 Product description

3.1 Field of application

The Exit and Safety luminaire is
suitable for operation on CEAG
safety lighting systems (e. g.
ZB 96 or CG 2000) as well as
on all power supply systems
acc. to VDE 0108, EMC
directive 89/336/EEC and low
potential directive 73/23/EEC.
The advanced switching mode
is available only with CEAG CG
2000 technology.

3.2 Technical data

Dimensions (L x H x D):
RZ 314 CG
220 x 110 x 80
RZ 324 CG
220 x 110 x 100
Material of
enclosure:
Sheet steel
Type of mounting:
RZ 314 CG
Wall mounted
RZ 324 CG
pendulum,
wall bracket
Weight (incl. cover):
RZ 314 CG
1.18 kg
RZ 324 CG with
penduluml
2.00 kg
RZ 324 CG with
wall bracket
1.82 kg
Terminals:
3 x 2.5 mm²
Input voltage: 230 V AC
50/60 Hz,
220 V DC
+25%/-20%
Rated current
(DC):
20 mA
Power consumption
(AC):
10 VA
Perm. ambient
temperature:
-10 °C .. +40 °C
Lamp:
4 W/T16
Isulation class: I
Protection category acc. to
EN 60529:
IP 20
2
2
1
1
0
0
9
8
Switch 1
Switch 2
Fig. 6

4 Installation

For the mounting and
operation of electrical
apparatus, the respec-
tive national safety regulations
(e. g. equipment safety law for
Germany) as well as the general
rules of engineering will have to
be observed.
Prior to installation turn off all
power supplies and secure
against unauthorized switching!
Pay attention to a tight fit of the
terminal screws! Unused cable
entries are left with their locking
plug fitted (IP protection).
RZ 314 CG only
Remove transport screen
and mounting plate from the
enclosure
Dowel mounting plate with
two screws.
Connect mains to terminals
L (U), N (0) and PE.
Address luminaire (see
chapter 5).
Fix enclosure to mounting
plate.
RZ 324 CG only
Remove transport screen
from the enclosure
Remove cover for pendulum
or wall bracket.
Connect mains to terminals
L (U), N (0) and PE.
Address luminaire (see
chapter 5).
Dowel pendulum or wall
bracket with two screws.
If necessary install luminaire
to wall bracket.
RZ 314 CG and RZ 324 CG
Insert lamp
Install panels
Mark luminaire.

5 Addressing

Before fitting the screen or
bowl, the addressing of the in-
3
dividual luminaires will have to
4
be performed. To do so, the de-
5
sired address (1 - 20) is set on
the address switch by means of
6
a suitable screw driver (Arrow-
7
head to No., fig. 6, 7, 8). If the
luminaire should not be moni-
tored the code 0/0 has to be
selected.
7