Varberg 3 570 x 525cm
Important informations
We are pleased that you have chosen a product of SKAN HOLZ.
Please check the construction set for completeness using the position list in good time before starting con-
struction or commissioning your construction team. If individual parts are defective or missing, we will deliver
these as quickly as possible. However, we cannot refund the costs for any resulting construction delays to a
construction company.
Please understand that we cannot assume any guarantee for the following defects:
- incorrect storage before assembly
- incorrect anchoring with the ground or inadequate foundation (foundation according to statics)
- damage due to erection errors, e. g. the house is not level or not right-angled
- damage through a higher level of snow burden than statically envisaged. Recommendation: lad relief of
the roof by removing the snow layer
- storm damage (insurance cases) or violent destruction
- damage through any alteration to the design by the client
- natural formation of cracks, branch holes, twisting, decolouration or similar modification (natural
process; has no influence on the statics)
Storage information until construction :
- store pallet on a level and dry surface. Tip: do not remove the foil and plastic straps until just before
assembly!
- Protect from exposure to sunlight and the influences of weather ; wood can warp drastically in a loose
condition!
Maintenance tips:
The wood is untreated. Accordingly, regular, protective coating is absolutely necessary!
Please observe the attached information sheet "Care instructions/Colour treatment".
To the drawings:
-
Foundation according (to the structural calculations, not included in the scope of delivery):
1
concrete C25/30, strip foundation: w/h = 30/90cm, each 2 Ø 12 top and bottom, bow Ø 6, e < 20cm.
Bottom panel: t=14cm,Q188A, top and bottom throughout. Anchoring of the floor beams on the strip
foundation using bolts M12, e < 60cm (by customer).
-
Given that the roof is constantly exposed to the weather, a covering with only one layer of roofing pa-
1
per will not be enough over the long-term. An additional covering with bitumen shingles, alternatively
with a material of at least equivalent quality, must follow.
© SKAN HOLZ Europe GmbH D-21227 Bendestorf. Technical modifications reserved. All dimensions are approximate dimensions. Date 01/13