Transient Load Response:
Temperature Coefficient:
Status Indication:
METER SPECIFICATIONS
Meter Types:
Meter Resolutions:
Meter Accuracies:
GENERAL
AC Input:
Power Consumption:
Operating Range:
Storage Range:
Environmental:
Safety:
EMC:
Size:
Weight:
4
<250us to within 50mV of set level for a 5% to 95% load change.
Typically <100ppm/°C
Output on lamp.
Constant voltage mode lamp.
Constant current mode lamp.
Unregulated (power limit) lamp
Trip message on display.
Dual 4 digit meters with 12.5mm (0.5") LEDs. Reading rate 4 Hz.
10mV, 10mA
Voltage 0.1% of reading ± 2 digits,
Current 0.3% of reading ± 2 digits
110V – 240V AC ± 10%, 50/60Hz.
Installation Category II.
1250VA max.
+5ºC to +40ºC, 20% to 80% RH.
−40ºC to + 70ºC.
Indoor use at altitudes up to 2000m, Pollution Degree 2.
Complies with EN61010-1.
Complies with EN61326.
210 x 130 x 375mm (WxHxD) half rack width x 3U height (optional
rack mounting kit available).
6kg