General specifications apply for the temperature range 5°C to 40°C. Accuracy specifications
apply for the temperature range 18°C to 28°C after 1 hour warm-up with no load and calibration at
23°C. Typical specifications are determined by design and are not guaranteed.
OUTPUT SPECIFICATIONS
Voltage Range:
Current Range:
Power Range:
Output Voltage Setting:
Output Current Setting:
Operating Mode:
Output Switch:
Output Terminals:
Sensing:
Output Protection:
Over-temperature Protection:
OVP Range:
Line Regulation:
Load Regulation:
Ripple & Noise
(20MHz bandwidth):
0V to 60V
0A to 20A
Up to 420W
By coarse and fine controls.
By single logarithmic control.
Constant voltage or constant current with automatic cross-over
provided that the power demanded stays within the power envelope,
see graph. Outside of this envelope the output becomes unregulated.
Electronic. Preset voltage and current displayed when off.
4mm terminals on 19mm (0·75") pitch. 30A max.
Switchable between local and remote. Spring-loaded push terminals
for remote connection.
Forward protection by Over-Voltage Protection (OVP) trip; maximum
voltage that should be applied to the terminals is 70V.
Reverse protection by diode clamp for reverse currents up to 3A.
The output will be tripped off if a fault causes the internal
temperature to rise excessively.
10% to 110% of maximum output voltage set by front panel
screwdriver adjustment.
Change in output for a 10% line change:
Constant voltage: <0.01% of maximum output
Constant current: <0.01% of maximum output
Change in output for any load change within PowerFlex envelope,
remote sense connected:
Constant voltage: <0.01% of maximum output
Constant current: <0.05% of maximum output
4mVrms max; typically <2mVrms, <10mV pk-pk, at maximum load,
CV mode.

Specification

XPF 60-20
POWER ENVELOPE