FUNCTIONALITIES
FIRST FILL-UP:
If the boiler and tank are completely empty, all system functions are disabled.
Ensure there is sufficient water in the tank, and manually fill if empty..
With the tank full and the boiler empty, after feeding the generator through the switches
(see the "PREPARATION" paragraph), the system controls the water filling pump until
the correct level is reached in t he boiler. In this phase the heating element is deact
ivated, while the signal lamp (4 fig.6) is on without blinking and without an acoustic
signal; this indicates the filling procedure in process.
Once filling is completed, the pump is turned off, an d h eating is simultaneously enabled
through the boiler heater; the signal lamp is turned off (4 fig.6).
LEVEL ADJUSTMENT:
BOILER:
Refilling i s carri ed out each ti me the level probe senses a low water level in the boiler.
During normal level refilling, the heating element remains enabled for heating and the signal
lamp (4 fig. 6) is o n without blinking and without acoustic signal.
If during filling the level probe located in the tank should remain exposed, the system
immediately stops refilling operations and the signal lamp (4 fig. 6) st arts blin king to
gether with an intermittent acoustic signal.
TANK:
Each time the tank level probe senses a low water level, the system immediately
stops refilling operations and the signal lamp (4 fig.6) starts blinking together with an
interrrmittent acoustic signal.
Refill the tank to reset the alarm.

ALARM SIGNALS:

If during the normal refilling phase the boiler level probe remains exposed for more
than 90 seconds consecutively, the heating element is tem porarily deactivated and is
reactivated at boiler leve l r ecovery since water r efilling in any case continues regularly.
WARING!
exposed for more than 3 minutes consecutively, the system disables heating and
refilling functions, and the signal lamp starts blinking along with an acoustic signal.
At this point the generator must be reset by turning the general switch off and then
back on (1 fig. 9).
If dur ing t he normal refilling p hase the boiler level probe remains